DESIGN AND CHARACTERIZATION OF LOW-COST SENSORS FOR AIR QUALITY MONITORING SYSTEM

Khakim, Mokhamad Yusup Nur (2018) DESIGN AND CHARACTERIZATION OF LOW-COST SENSORS FOR AIR QUALITY MONITORING SYSTEM. Jurnal Pendidikan IPA Indonesia, 7 (3). pp. 347-354. ISSN 23391286

[thumbnail of Rumantari2018_JPII.pdf] Text
Rumantari2018_JPII.pdf

Download (458kB)

Abstract

In this study, low-cost sensors for air quality monitoring system have been characterized and designed. These sensors are applied in a monitoring system and installed at Sriwijaya University, which is vulnerable to the im�pacts of forest fires in the surrounding area. This monitoring system will provide information especially for the university community to determine the level of air quality on campus. In this research the researchers focussed on the characterization and design of system sensor that aimed to get the best configuration of low-cost sensors namely MQ-7, Sharp GP2Y1010AU0F and own-designed smoke sensor to have high reliability and effectiveness to be applied to monitoring systems. The test results showed that the sensors have good response and sensitivity. Therefore, it can be applied to the monitoring system to provide information about the level of particle concentra�tion, carbon monoxide and smoke which meet the needs of low-cost monitoring systems.

Item Type: Article
Subjects: #3 Repository of Lecturer Academic Credit Systems (TPAK) > Articles Access for TPAK (Not Open Sources)
Divisions: 08-Faculty of Mathematics and Natural Science > 45102-Physics (S2)
Depositing User: Mokhamad Yusup Nur Khakim
Date Deposited: 19 May 2023 12:24
Last Modified: 19 May 2023 12:24
URI: http://repository.unsri.ac.id/id/eprint/103785

Actions (login required)

View Item View Item