PERBANDINGAN METODE KONDUKTOMETRI DAN SPEKTROFOTOMETRI UV-Vis TERHADAP ANALISIS ION LOGAM BESI (III) PADA AIR SUNGAI MUSI

FATRIN, LIDIA and Fatma, Fatma (2019) PERBANDINGAN METODE KONDUKTOMETRI DAN SPEKTROFOTOMETRI UV-Vis TERHADAP ANALISIS ION LOGAM BESI (III) PADA AIR SUNGAI MUSI. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_47201_08031381924057.pdf] Text
RAMA_47201_08031381924057.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_47201_08031381924057_TURNITIN.pdf] Text
RAMA_47201_08031381924057_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_47201_08031381924057_0013076209_01_front_ref.pdf] Text
RAMA_47201_08031381924057_0013076209_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (2MB)
[thumbnail of RAMA_47201_08031381924057_0013076209_02.pdf] Text
RAMA_47201_08031381924057_0013076209_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (368kB) | Request a copy
[thumbnail of RAMA_47201_08031381924057_0013076209_03.pdf] Text
RAMA_47201_08031381924057_0013076209_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (254kB) | Request a copy
[thumbnail of RAMA_47201_08031381924057_0013076209_04.pdf] Text
RAMA_47201_08031381924057_0013076209_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (288kB) | Request a copy
[thumbnail of RAMA_47201_08031381924057_0013076209_05.pdf] Text
RAMA_47201_08031381924057_0013076209_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (198kB) | Request a copy
[thumbnail of RAMA_47201_08031381924057_0013076209_06_ref.pdf] Text
RAMA_47201_08031381924057_0013076209_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (211kB) | Request a copy
[thumbnail of RAMA_47201_08031381924057_0013076209_07_lamp.pdf] Text
RAMA_47201_08031381924057_0013076209_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (565kB) | Request a copy

Abstract

Human activities such as industrial, agricultural, and household activities around the Musi river can cause contamination of heavy metals into the Musi river body. Iron is a type of heavy metal that can pollute the environment. Therefore, it is necessary to test the iron content in Musi River water as an effort to prevent water pollution. This research aims to compare the conductometric and spectrophotometric UV-Vis methods to the analysis of iron (III) metal ions in Musi river water. The validation results of the conductometric method obtained linearity and sensitivity values of 0.9965 and 0.1907 mg/L, detection limit and quantization limit obtained 0.172 mg/L and 0.260 mg/L, precision and accuracy of 2% and 96.48%. The results of the verification of the UV-Vis spectrophotometric method obtained linearity and sensitivity values of 0.9989 and 0.0322 mg/l, limit of detection and quantization limit of 0.096 mg/L and 0.205 mg/L, precision and accuracy of 4% and 94.4%. The metal ion level of iron (III) in Musi river water by using conductometric and has shown 1.49 mg/L and 2.07 mg/L as the result. The results of the analysis of ferrous (III) metal ions from the two methods were tested using t-test in the SPSS application. The t-test results show the tcount value of 2.35, which is smaller than the ttable value of 2.78 at 95% of confidence level. From the results that have been found, it can be stated that the two methods have no statistically significant difference, so the analysis of ferrous (III) metal ions can be carried out using both methods with an estimated uncertainty measurement conductometric of 1.49 + 0.09 mg/L and spectrophotometry UV-Vis 2.07 + 0.06 mg/L.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: konduktometri, spektrofotometri UV-Vis, ion logam besi (III), uji-t
Subjects: Q Science > QD Chemistry > QD71-142 Analytical chemistry
Divisions: 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1)
Depositing User: Lidia Fatrin
Date Deposited: 29 May 2023 04:07
Last Modified: 29 May 2023 04:07
URI: http://repository.unsri.ac.id/id/eprint/105737

Actions (login required)

View Item View Item