MUBARAK, OMAR NABIL and Ariani, Menik (2023) DISTRIBUSIS DOSIS RADIASI PADA SISTEM PENYINARAN PANORAMIK CS-137 MENGGUNAKAN DOSIMETER OSL (OPTICALLY STIMULATED LUMINESCENCE) DAN SURVEYMETER. Undergraduate thesis, Sriwijaya University.
Text
RAMA_45201_08021281924030.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
|
Text
RAMA_45201_08021281924030_TURNITIN.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (6MB) | Request a copy |
|
Text
RAMA_45201_08021281924030_0025117201_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (737kB) |
|
Text
RAMA_45201_08021281924030_0025117201_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (378kB) | Request a copy |
|
Text
RAMA_45201_08021281924030_0025117201_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (335kB) | Request a copy |
|
Text
RAMA_45201_08021281924030_0025117201_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (229kB) | Request a copy |
|
Text
RAMA_45201_08021281924030_0025117201_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (128kB) | Request a copy |
|
Text
RAMA_45201_08021281924030_0025117201_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (231kB) | Request a copy |
|
Text
RAMA_45201_08021281924030_0025117201_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (386kB) | Request a copy |
Abstract
Radiation dose distribution has been carried out on the Cs-137 panoramic irradiation system using an OSL dosimeter and a survey meter. This study was conducted to determine the response of the OSL dosimeter and determine the dose rate on the Cs-137 panoramic irradiation system. The method was carried out by preparing 5 groups of OSL dosimeters, each of which was 6 dosimeters installed at positions 1 to 6 and irradiated with Cs-137 gamma radiation of 0.25 mSv, 0.50 mSv, 1 mSv, 2.5 mSv, 5 mSv and control. To measure the radiation dose rate it was prepared a set of Xi surveymeter with XI view raysafe software. Personnel dose response or Hp(10) to irradiation time shows a linear curve at positions 1 to 6 with a strong correlation of 0.9985 – 0.9997. The ratio of reading dose to irradiation dose is relatively small for lower irradiation doses. For higher irradiation doses, the rasio of reading dose to irradiation dose is relatively large . The value of the dose rate on the Cs-137 panoramic irradiation system using a surveymeter shows that the highest dose rate is at position 6 with a value of 0.985 mSv/hour and the lowest dose rate is at position 3 with a value of 0.933 mSv/hour. The uncertainty value on the surveymeter tool from positions 1 to 6 it ranges from 2.0% to 3.4%.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | panoramik, Cs-137, dosimeter OSL, dosis, surveymeter, laju dosis |
Subjects: | Q Science > QC Physics > QC794.95-798 Radioactivity and radioactive substances |
Divisions: | 08-Faculty of Mathematics and Natural Science > 45201-Physics (S1) |
Depositing User: | Omar Nabil Mubarak |
Date Deposited: | 01 Jun 2023 04:39 |
Last Modified: | 01 Jun 2023 04:39 |
URI: | http://repository.unsri.ac.id/id/eprint/106396 |
Actions (login required)
View Item |