ANALISA GANGGUAN HUBUNG SINGKAT SATU FASA KE TANAH MENGGUNAKAN SETTING GROUND FAULT RELAY (GFR) PADA TRANSFORMATOR 30 MVA DI GARDU INDUK BOOM BARU

KAMILAH, RAIDAH SABRINA and Adipradana, Wirawan (2023) ANALISA GANGGUAN HUBUNG SINGKAT SATU FASA KE TANAH MENGGUNAKAN SETTING GROUND FAULT RELAY (GFR) PADA TRANSFORMATOR 30 MVA DI GARDU INDUK BOOM BARU. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_20201_03041381924084.pdf] Text
RAMA_20201_03041381924084.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (4MB) | Request a copy
[thumbnail of RAMA_20201_03041381924084_TURNITIN.pdf] Text
RAMA_20201_03041381924084_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (5MB) | Request a copy
[thumbnail of RAMA_20201_03041381924084_0012018605_01_front_ref.pdf] Text
RAMA_20201_03041381924084_0012018605_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_20201_03041381924084_0012018605_02.pdf] Text
RAMA_20201_03041381924084_0012018605_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (421kB) | Request a copy
[thumbnail of RAMA_20201_03041381924084_0012018605_03.pdf] Text
RAMA_20201_03041381924084_0012018605_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (207kB) | Request a copy
[thumbnail of RAMA_20201_03041381924084_0012018605_04.pdf] Text
RAMA_20201_03041381924084_0012018605_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (384kB) | Request a copy
[thumbnail of RAMA_20201_03041381924084_0012018605_05.pdf] Text
RAMA_20201_03041381924084_0012018605_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (106kB) | Request a copy
[thumbnail of RAMA_20201_03041381924084_0012018605_06_ref.pdf] Text
RAMA_20201_03041381924084_0012018605_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (109kB) | Request a copy
[thumbnail of RAMA_20201_03041381924084_0012018605_07_lamp.pdf] Text
RAMA_20201_03041381924084_0012018605_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy

Abstract

At present the community's need for electrical energy consumption increases from year to year at the Boom Baru Substation, so that the electric power system must be able to guarantee in terms of availability and quality of service. One form of transformer disturbance that often occurs in substations is NGR. Neutral Grounding Resistor (NGR) which is one of the grounding systems that functions as a current limiter or minimizes fault currents, especially single-phase short-circuit faults to ground. The NGR also sends a signal through the current transformer to the Ground Fault Relay (GFR) which functions to break the circuit breaker if the fault current exceeds that obtained by the transformer. Therefore, it is necessary to re-calculate to determine the condition and readiness of safety equipment to maintain the reliability of the electric power system. Therefore the author performs a one-phase-to-ground short circuit fault analysis using the Ground Fault Relay (GFR) setting on a 30 MVA transformer at the Boom Baru Substation by using short circuit fault analysis calculations and also calculating ground fault relay settings. The calculation results obtained on the value of the single-phase short-circuit current to ground using R = 40 ꭥ at a location with a fault of 25% at the date feeder is 277.2337 A. while the short-circuit current value of one-phase to ground with solid grounding at the location of the fault of 25% on date feeders is 579.4504 A. so using NGR is much better than solid grounding. From the results of calculating the GFR setting using the Standard Inverse characteristic, the TMS value has the same magnitude for each feeder, which is equal to 0.1 SI.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Transformator, NGR, GFR, Hubung Singkat, Pentanahan Langsung
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3001-3521 Distribution or transmission of electric power
Divisions: 03-Faculty of Engineering > 20201-Electrical Engineering (S1)
Depositing User: Raidah Sabrina Kamilah
Date Deposited: 12 Jul 2023 07:49
Last Modified: 12 Jul 2023 07:49
URI: http://repository.unsri.ac.id/id/eprint/116217

Actions (login required)

View Item View Item