EVALUASI KESALAHAN RADIOGRAF PERIAPIKAL DENGAN TEKNIK BISEKTRIS DI RSKGM PROVINSI SUMATERA SELATAN

HAMSANI, ABDULLAH and Prativi, Shinta Amini and Yulianti, Rinda (2023) EVALUASI KESALAHAN RADIOGRAF PERIAPIKAL DENGAN TEKNIK BISEKTRIS DI RSKGM PROVINSI SUMATERA SELATAN. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_12201_04031281924045.pdf] Text
RAMA_12201_04031281924045.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (4MB) | Request a copy
[thumbnail of RAMA_12201_04031281924045_TURNITIN.pdf] Text
RAMA_12201_04031281924045_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_12201_04031281924045_0022088805_0031018401_01_front_ref.pdf] Text
RAMA_12201_04031281924045_0022088805_0031018401_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (4MB)
[thumbnail of RAMA_12201_04031281924045_0022088805_0031018401_02.pdf] Text
RAMA_12201_04031281924045_0022088805_0031018401_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (736kB) | Request a copy
[thumbnail of RAMA_12201_04031281924045_0022088805_0031018401_03.pdf] Text
RAMA_12201_04031281924045_0022088805_0031018401_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (607kB) | Request a copy
[thumbnail of RAMA_12201_04031281924045_0022088805_0031018401_04.pdf] Text
RAMA_12201_04031281924045_0022088805_0031018401_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (254kB) | Request a copy
[thumbnail of RAMA_12201_04031281924045_0022088805_0031018401_05.pdf] Text
RAMA_12201_04031281924045_0022088805_0031018401_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (8kB) | Request a copy
[thumbnail of RAMA_12201_04031281924045_0022088805_0031018401_06_ref.pdf] Text
RAMA_12201_04031281924045_0022088805_0031018401_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (128kB) | Request a copy
[thumbnail of RAMA_12201_04031281924045_0022088805_0031018401_07_lamp.pdf] Text
RAMA_12201_04031281924045_0022088805_0031018401_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy

Abstract

Background: One of the radiographs commonly used in dentistry is periapical radiography. Periapical radiograph results can be subject to various errors that affect interpretation, diagnosis, and treatment planning. The aim of this study was to evaluate the periapical radiograph error bisecting technique error at RSKGM South Sumatra Province. Method: The type of this study was descriptive observational that evaluates 219 periapical radiographs at RSKGM South Sumatra Province from 2015-2023. Periapical radiograph errors are categorized into 15 types of errors, namely dark radiograph, light radiograph, apex missing, dropped receptor corner, elongation, foreshortening, overlapped contacts, cone-cut, blurring, reticulation of emulsion, dark spot or line, light spot or line, yellow -brown color, developer cutoff, and fixer cutoff. The reliability test was conducted using Cohen's Kappa analysis. Results: Evaluation of 219 radiographs showed that there were 712 errors with the five most common errors being apex missing (20.08%), dropped receptor corner (14.18%), overlapped contacts (13.20%), dark spot or line (12.92% ), and light spot or line (12.78%). Conclusion: Periapical radiograph errors at RSKGM South Sumatra Province are still quite high and must be minimized to improve the quality of radiographs in the future.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: bisektris, kesalahan, periapikal, radiograf
Subjects: R Medicine > RK Dentistry > RK1-715 Dentistry
Divisions: 04-Faculty of Medicine > 12201-Dentistry (S1)
Depositing User: Abdullah Hamsani
Date Deposited: 12 Oct 2023 05:16
Last Modified: 12 Oct 2023 05:16
URI: http://repository.unsri.ac.id/id/eprint/129780

Actions (login required)

View Item View Item