ADHIWIBOWO, TRIE and Kuncoro, Endo Argo and Haskari, Farry Apriliano (2017) MODIFIKASI SHOWCASE MENJADI DUA FUNGSI UNTUK MENGHANGATKAN DAN MENDINGINKAN DENGAN MENGGUNAKAN MIKROKONTROLER AVR AT MEGA 16. Undergraduate thesis, Sriwijaya University.
Preview |
Text
RAMA_41201_05021281320015_0014047607_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (1MB) | Preview |
Text
RAMA_41201_05021281320015_0014047607_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (401kB) | Request a copy |
|
Text
RAMA_41201_05021281320015_0014047607_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (251kB) | Request a copy |
|
Text
RAMA_41201_05021281320015_0014047607_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (340kB) | Request a copy |
|
Text
RAMA_41201_05021281320015_0014047607_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (127kB) | Request a copy |
|
Text
RAMA_41201_05021281320015_0014047607_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (242kB) | Request a copy |
|
Text
RAMA_41201_05021281320015_0014047607_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
Abstract
This research used showcase as cooling engine, the lamp as heat source, Microcontroller AVR AT Mega 16 as equipment control, sensor LM35 as the reader of temperature in the storage and sensor SHT11 as a measure of humidity in the storage. The result of research showed the chances of temperature and humidity inside the storage that had function to heat and cool by using AVR AT Mega 16 as system control. The changes of temperature and humidity proved that the showcase modification for heating and cooling by using Microcontroller AVR AT Mega 16 can function well, according to the developed program.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Microcontroller AVR AT Mega 16, temperature, showcase. |
Subjects: | S Agriculture > S Agriculture (General) > S1-(972) Agriculture (General) |
Divisions: | 05-Faculty of Agriculture > 41201-Agricultural Engineering (S1) |