PENGARUH TEGANGAN LISTRIK TERHADAP HASIL KOAGULASI PADA ALAT ELEKTROFORESIS KOLOID

RISALAWATI, RISALAWATI and Suharman, Andi and Sanjaya, Sanjaya (2024) PENGARUH TEGANGAN LISTRIK TERHADAP HASIL KOAGULASI PADA ALAT ELEKTROFORESIS KOLOID. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_84204_0610282025021.pdf] Text
RAMA_84204_0610282025021.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_84204_0610282025021_TURNITIN.pdf] Text
RAMA_84204_0610282025021_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_84204_0610282025021_0017116507_0007036305_01_front_ref.pdf] Text
RAMA_84204_0610282025021_0017116507_0007036305_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (535kB)
[thumbnail of RAMA_84204_0610282025021_0017116507_0007036305_02.pdf] Text
RAMA_84204_0610282025021_0017116507_0007036305_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (49kB) | Request a copy
[thumbnail of RAMA_84204_0610282025021_0017116507_0007036305_03.pdf] Text
RAMA_84204_0610282025021_0017116507_0007036305_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (81kB) | Request a copy
[thumbnail of RAMA_84204_0610282025021_0017116507_0007036305_04.pdf] Text
RAMA_84204_0610282025021_0017116507_0007036305_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (964kB) | Request a copy
[thumbnail of RAMA_84204_0610282025021_0017116507_0007036305_05.pdf] Text
RAMA_84204_0610282025021_0017116507_0007036305_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (7kB) | Request a copy
[thumbnail of RAMA_84204_0610282025021_0017116507_0007036305_06_ref.pdf] Text
RAMA_84204_0610282025021_0017116507_0007036305_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (142kB) | Request a copy
[thumbnail of RAMA_84204_0610282025021_0017116507_0007036305_07_lamp.pdf] Text
RAMA_84204_0610282025021_0017116507_0007036305_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy

Abstract

Electrophoresis is a technique that can be used to determine the type of charge in a colloid. Colloidal particles when an electric current flows through them will move towards the electrode with the opposite charge. This research aims to determine the effect of the electric voltage on the coagulation results in a colloid electrophoresis device and to determine the optimum electric voltage. The samples in this study were milk, coconut milk, Fe(OH)3, and Al(OH)3. Each sample was tested at various electrical voltages, namely 10 V, 15 V, 20 V, 25 V, and 30 V with repetition three times. Each test was carried out for 15 minutes. The independent variable in this research is electric voltage, while the dependent variable is the sample deposition result. Based on the results data obtained, there is a significant but small influence between the electric voltage and the coagulation results, namely the higher the magnitude of the electric voltage, the greater the coagulation mass obtained. The results of the research showed that the electric voltage and milk and coconut milk samples contained colloidal particles clumping on the positive electrode (anode), this means that the colloidal particles were negatively charged. Meanwhile, in the Fe(OH)3 and Al(OH)3 samples there are colloidal particles clumping on the negative electrode (cathode), this means that the colloidal particles have a negative charge. From this test, the optimum voltage is obtained according to the capacity of the tool, namely 30 V. Keywords: Colloid, electrophoresis, voltage, effect.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Koloid, elektroforesis, tegangan listrik, pengaruh
Subjects: Q Science > QD Chemistry > QD1-999 Chemistry
Q Science > QD Chemistry > QD450-801 Physical and theoretical chemistry
Q Science > QD Chemistry > QD71-142 Analytical chemistry
Divisions: 06-Faculty of Education and Educational Science > 84204-Chemistry Education (S1)
Depositing User: Risalawati Risalawati
Date Deposited: 29 May 2024 05:42
Last Modified: 29 May 2024 05:42
URI: http://repository.unsri.ac.id/id/eprint/146012

Actions (login required)

View Item View Item