NAINGGOLAN, PARMAN and Barlin, Barlin (2014) KAJIAN KINERJA SISTEM PEMOMPAAN CLARIFIED WATER DARI CLEAR WELL KE SAN D FILTER DI PT. PUPUK SRIWIDJAJA PALEMBANG (PERSERO). Undergraduate thesis, Sriwijaya University.
Text
RAMA_21201_03081005068.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (31MB) | Request a copy |
|
Text
RAMA_21201_03081005068_0030068102_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (8MB) |
|
Text
RAMA_21201_03081005068_0030068102_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (8MB) | Request a copy |
|
Text
RAMA_21201_03081005068_0030068102_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
|
Text
RAMA_21201_03081005068_0030068102_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (3MB) | Request a copy |
|
Text
RAMA_21201_03081005068_0030068102_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (674kB) | Request a copy |
|
Text
RAMA_21201_03081005068_0030068102_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (372kB) | Request a copy |
|
Text
RAMA_21201_03081005068_0030068102_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (8MB) | Request a copy |
Abstract
PT. Fertilizer Sriwidjaja Palembang (Persero) is the first of urea fertilizer planl. The pump has an importanl role lo move the fluid from one place to another. This study was conducted t o analyze the performance of a water pumping system as a whole t o determine the pump efficiency by comparing actual performance and the performance of the design . The results of this study indicate that the pump decreased performance due to damage to the head of 10 m (design ) to 9 m (actual) , motor power 75 kW ( design ) to 78 kW (actual) , and efficiency of 15 % (design ) to 12 , 1 % (actual) .From the pump to the system head curve pump head design , there are intersecting lines between the pump head system w i t h pump head design that shows the working poin t pump with a capacity of 0,138 m /s2.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Pump, System, performance and efisiensi |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ1-1570 Mechanical engineering and machinery |
Divisions: | 03-Faculty of Engineering > 21201-Mechanical Engineering (S1) |
Depositing User: | Mrs Furika Furika |
Date Deposited: | 03 Jun 2024 02:39 |
Last Modified: | 03 Jun 2024 02:39 |
URI: | http://repository.unsri.ac.id/id/eprint/146185 |
Actions (login required)
View Item |