SUTANTO J. S., CRIS and Yanto, Joni and Santoso, Dyos (2013) EVALUASI KINERJA SISTEM PEMOMPAAN LIMBAH MINYAK PADA HVU-II PT. PERTAMINA R U-III PLAJU-SUNGAI GERONG PALEMBANG. Undergraduate thesis, Sriwijaya University.
Text
RAMA_21201_03081005090.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (38MB) | Request a copy |
|
Text
RAMA_21201_03081005090_0022055703_0023126009_01_front_ref.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (9MB) | Request a copy |
|
Text
RAMA_21201_03081005090_0022055703_0023126009_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (12MB) | Request a copy |
|
Text
RAMA_21201_03081005090_0022055703_0023126009_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (3MB) | Request a copy |
|
Text
RAMA_21201_03081005090_0022055703_0023126009_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (3MB) | Request a copy |
|
Text
RAMA_21201_03081005090_0022055703_0023126009_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (381kB) | Request a copy |
|
Text
RAMA_21201_03081005090_0022055703_0023126009_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (610kB) | Request a copy |
|
Text
RAMA_21201_03081005090_0022055703_0023126009_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (9MB) | Request a copy |
Abstract
Centrifugal pump is one type of pump that has a very wide scope of use associated with the head and the resulting capacity. Various aitempts have been made in the design world to produce a centrifugal pump with the characteristics and performance of the maximum. This study intend t o compare the actual performance pump with design performance and determine the cause of the damage. The results showed that the pump working point for a new pipeline conditions are at Q = 0,0035 m3/s, H = 61 m and rj = 44%, for the condition of the pipeline with age ± 20 years, working point of the pump in Q = 0,001946 m3/s, H — 67,7 m and rj = 23,7%, and to operating conditions in field were at the time of discharge valve condition in a partially unopened (Throttling Valve) point pumps were working in O = 0,00139 m3/s, H = 69,97 m and r\ — 16,7%.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Waste pumping, flush pump, pump performance and design conditions. |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ1-1570 Mechanical engineering and machinery |
Divisions: | 03-Faculty of Engineering > 21201-Mechanical Engineering (S1) |
Depositing User: | Mrs Furika Furika |
Date Deposited: | 03 Jun 2024 03:00 |
Last Modified: | 03 Jun 2024 03:00 |
URI: | http://repository.unsri.ac.id/id/eprint/146186 |
Actions (login required)
View Item |