MULAWARMAN, M. ADITYA and Santoso, Dyos (2014) ANALISIS KINERJA POMPA MINYAK MENTAH PADA STASIUN PUSAT PEMOMPAAN DAN PRODUKSI TEMPINO - JAMBI. Undergraduate thesis, Sriwijaya University.
Text
RAMA_21201_03101405050.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (30MB) | Request a copy |
|
Text
RAMA_21201_03101405050_0023126009_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (8MB) |
|
Text
RAMA_21201_03101405050_0023126009_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (7MB) | Request a copy |
|
Text
RAMA_21201_03101405050_0023126009_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (3MB) | Request a copy |
|
Text
RAMA_21201_03101405050_0023126009_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (4MB) | Request a copy |
|
Text
RAMA_21201_03101405050_0023126009_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (522kB) | Request a copy |
|
Text
RAMA_21201_03101405050_0023126009_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (202kB) | Request a copy |
|
Text
RAMA_21201_03101405050_0023126009_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (6MB) | Request a copy |
Abstract
Central Sumatra region Pertagas inc. Uses centrifugal pump as erude oil dis t ribut ion iool from wells which located in Jambi province t o Pertamina R U III Sungai Gerong t o be processed into several distinetive produets. This final project set centrifugal pump as research object which ai/ns t o evaluate the performance ofthat particular oump. By setting cyrva head system, obtained pump Jlow in 2982 rpm is 0,0165 m3/s, head as big as 470 m, power about 92 k\V and 65% efficiency. In this term, pump works in Best Efficiency Point and operating well in recommended range from 0,0129 m3/s t o 0,0178 m3Vs.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Centrifugal Pump, Head System. Best efficiency Point |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ1-1570 Mechanical engineering and machinery |
Divisions: | 03-Faculty of Engineering > 21201-Mechanical Engineering (S1) |
Depositing User: | Mrs Furika Furika |
Date Deposited: | 05 Jun 2024 04:07 |
Last Modified: | 05 Jun 2024 04:07 |
URI: | http://repository.unsri.ac.id/id/eprint/146268 |
Actions (login required)
View Item |