ESTIMASI DOSIS HP (3) DAN HP (10) MENGGUNAKAN PHANTOM PADA PESAWAT SINAR-X KONVENSIONAL

SILABAN, ANGGELIKA BR and Ramlan, Ramlan (2024) ESTIMASI DOSIS HP (3) DAN HP (10) MENGGUNAKAN PHANTOM PADA PESAWAT SINAR-X KONVENSIONAL. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_45201_08021282025045.pdf] Text
RAMA_45201_08021282025045.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (12MB) | Request a copy
[thumbnail of RAMA_45201_08021282025045_TURNITIN.pdf] Text
RAMA_45201_08021282025045_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_45201_08021282025045_0010046604_01_front_ref.pdf] Text
RAMA_45201_08021282025045_0010046604_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_45201_08021282025045_0010046604_02.pdf] Text
RAMA_45201_08021282025045_0010046604_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (384kB) | Request a copy
[thumbnail of RAMA_45201_08021282025045_0010046604_03.pdf] Text
RAMA_45201_08021282025045_0010046604_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (347kB) | Request a copy
[thumbnail of RAMA_45201_08021282025045_0010046604_04.pdf] Text
RAMA_45201_08021282025045_0010046604_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (247kB) | Request a copy
[thumbnail of RAMA_45201_08021282025045_0010046604_05.pdf] Text
RAMA_45201_08021282025045_0010046604_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (127kB) | Request a copy
[thumbnail of RAMA_45201_08021282025045_0010046604_06_ref.pdf] Text
RAMA_45201_08021282025045_0010046604_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (201kB) | Request a copy
[thumbnail of RAMA_45201_08021282025045_0010046604_07_lamp.pdf] Text
RAMA_45201_08021282025045_0010046604_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (10MB) | Request a copy

Abstract

The measurement of estimated doses of Hp (3) and Hp (10) radiation using a phantom aims to further study the estimated dose of HP (3) with the use of the Hp (10) dose as The basis for the application of radiation protection. The thermoluminesce dosimeter is heated to clear the residues of radiation previously absorbed using the annealing method with the help of furnace and oven tools. The TLD is radiated using an X-ray plane to obtain radiation dose values. The TLD was read with the Harshaw 3500 TLD Reader to determine the dose absorbed by the TLD. The dose value produced was 0.0608 mGy in the chest and 0.0884 mGy in the eye this dose value does not exceed the recommended dose limit value so that it does not harm the patient or the general public.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Sinar-X, Phantom
Subjects: Q Science > QC Physics > QC770-798 Nuclear and particle physics. Atomic energy. Radioactivity
Divisions: 08-Faculty of Mathematics and Natural Science > 45201-Physics (S1)
Depositing User: Anggelika Br Silaban
Date Deposited: 21 Aug 2024 08:20
Last Modified: 21 Aug 2024 08:20
URI: http://repository.unsri.ac.id/id/eprint/155853

Actions (login required)

View Item View Item