SPESIASI ION LOGAM CR(III) DAN CR(VI) PADA TANAMAN ECENG GONDOK (EICHHORNIA CRASSIPES) MENGGUNAKAN METODE POTENSIOMETRI SEL KONSENTRASI

INDRIANI, RESTI ATIKA and Suheryanto, Suheryanto (2024) SPESIASI ION LOGAM CR(III) DAN CR(VI) PADA TANAMAN ECENG GONDOK (EICHHORNIA CRASSIPES) MENGGUNAKAN METODE POTENSIOMETRI SEL KONSENTRASI. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_47201_08031182025016.pdf] Text
RAMA_47201_08031182025016.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_47201_08031182025016_TURNITIN.pdf] Text
RAMA_47201_08031182025016_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_47201_08031182025016_0025066004_01_front_ref.pdf] Text
RAMA_47201_08031182025016_0025066004_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_47201_08031182025016_0025066004_02.pdf] Text
RAMA_47201_08031182025016_0025066004_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (621kB) | Request a copy
[thumbnail of RAMA_47201_08031182025016_0025066004_03.pdf] Text
RAMA_47201_08031182025016_0025066004_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (521kB) | Request a copy
[thumbnail of RAMA_47201_08031182025016_0025066004_04.pdf] Text
RAMA_47201_08031182025016_0025066004_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (493kB) | Request a copy
[thumbnail of RAMA_47201_08031182025016_0025066004_05.pdf] Text
RAMA_47201_08031182025016_0025066004_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (179kB) | Request a copy
[thumbnail of RAMA_47201_08031182025016_0025066004_06_ref.pdf] Text
RAMA_47201_08031182025016_0025066004_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (197kB) | Request a copy
[thumbnail of RAMA_47201_08031182025016_0025066004_07_Lamp.pdf] Text
RAMA_47201_08031182025016_0025066004_07_Lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (895kB) | Request a copy

Abstract

Water hyacinth is a bioindicator plant that has high tolerance to metal pollutans concentration of Cr(III) and Cr(VI) metal ions species in Ogan river. Measurement of Cr(III) and Cr(VI) metal ions species has done using the concentration cell potentiometric method. This study aims to validated the method (linearity, precision, accuracy, LoD & LoQ). Applying the concentration cell potentiometric method to measure Cr(III) and Cr(VI) metal ion species in water hyacinth plants in the Ogan river and determining the distribution of Cr(III) and Cr(VI) metal ion species founded in water hyacinth plants at each sampling location. The result showed that the concentration cell potentiometric method was proven to be valid with the Cr(III) and Cr(VI) regression equations respectively y = 8.4768x + 0.3051 and y = 4.1074x + 0.3145, the correlation determination obtained were respectively equal to 0.999 and 0.998. The precision obtained for the metal ions Cr(III) and Cr(VI) was 0.333% and 1.095%. The accuracy obtained for the metal ions Cr(III) and Cr(VI) was 95.33% and 94.38%. The LoD and LoQ values of the method obtained for Cr(III) were respectively 0.5016 mg/L and 0.502 mg/L while the LoD and LoQ of the method for Cr(VI) were obtained respectively 0.482 mg/L and 0.483 mg/L. The highest concentrations of Cr(III) and Cr(VI) metal ions measured from water hyacinth plants parts were highest in the roots. The highest distribution of Cr(III) metal ion contamination is at location Pegayut and the lowest is at location 15 Ulu, while for Cr(VI) metal ion the highest is at location 15 Ulu and the lowest is at location Ulu Laut.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Spesiasi, Potensiometri Sel Konsentrasi, Eceng Gondok (Eichhorniacrassipes), Kromium.
Subjects: Q Science > QD Chemistry > QD71-142 Analytical chemistry
Divisions: 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1)
Depositing User: Resti Atika Indriani
Date Deposited: 20 Sep 2024 02:00
Last Modified: 20 Sep 2024 02:00
URI: http://repository.unsri.ac.id/id/eprint/157657

Actions (login required)

View Item View Item