ISWORO, MARHAINDRA GARY and Kaprawi, Kaprawi (2014) ANALISA EFEK KONFIGURASI KOIL PEMANAS TERHADAP TEMPERATUR DAN DISTRIBUSI ALIRAN UDARA DIDALAM PENGERING KAYU JENIS KOMPARTEMEN MENGGUNAKAN CFD. Undergraduate thesis, Sriwijaya University.
Text
RAMA_21201_03091005009.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (107MB) | Request a copy |
|
Text
RAMA_21201_03091005009_0018015703_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (20MB) |
|
Text
RAMA_21201_03091005009_0018015703_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (24MB) | Request a copy |
|
Text
RAMA_21201_03091005009_0018015703_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (12MB) | Request a copy |
|
Text
RAMA_21201_03091005009_0018015703_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (31MB) | Request a copy |
|
Text
RAMA_21201_03091005009_0018015703_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
|
Text
RAMA_21201_03091005009_0018015703_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
|
Text
RAMA_21201_03091005009_0018015703_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (16MB) | Request a copy |
Abstract
Problem that exists in the timber industry in particularly process of reducing water content in the wood using compartment kiln is heating coil configuration wilhin the kiln. In this research, the coil installation will be determined the best of coil installations by taking samples from the factories by looking at the heat and airflow distribution uniformity within the kiln. Method of This study is CFD (Computational Fluid Dynamic) analysis by Software Flovent 9. J. There are 3 variables of coil configuration, the coil placed horizontally (parallel to the fluid flow of the fan), vertically (perpendicular to the fluid flow), and with slope of 57°. This research concluded that the position of the coils have uniform distribution ofheat and air flow is in the horizontal position or parallel to the direction of air flow. Coil installation vertically has a good uniformity of air flow distribution and with highest efficiency of thermal.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Compartment Kiln, CFD, Heating Coil |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ1-1570 Mechanical engineering and machinery |
Divisions: | 03-Faculty of Engineering > 21201-Mechanical Engineering (S1) |
Depositing User: | Mrs Furika Furika |
Date Deposited: | 28 Oct 2024 08:10 |
Last Modified: | 28 Oct 2024 08:10 |
URI: | http://repository.unsri.ac.id/id/eprint/158934 |
Actions (login required)
View Item |