AZZAHRA, PUTRI and Said, Muhammad (2025) SINTESIS DAN KARAKTERISASI LAPISAN TIPIS DLC/Ti/Cu PADA PERMUKAAN STAINLESS STEEL 316 MENGGUNAKAN METODE PECVD DAN PVD SEBAGAI BAHAN BIOMATERIAL IMPLAN TULANG. Undergraduate thesis, Sriwijaya University.
![]() ![]() Preview |
Image
RAMA_47201_08031182126010_cover.jpg - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (450kB) | Preview |
![]() |
Text
RAMA_47201_08031182126010.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (3MB) | Request a copy |
![]() |
Text
RAMA_47201_08031182126010_TURNITIN.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (4MB) | Request a copy |
![]() |
Text
RAMA_47201_08031182126010_0021077406_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (1MB) |
![]() |
Text
RAMA_47201_08031182126010_0021077406_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (308kB) | Request a copy |
![]() |
Text
RAMA_47201_08031182126010_0021077406_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (164kB) | Request a copy |
![]() |
Text
RAMA_47201_08031182126010_0021077406_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
![]() |
Text
RAMA_47201_08031182126010_0021077406_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (30kB) | Request a copy |
![]() |
Text
RAMA_47201_08031182126010_0021077406_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (121kB) | Request a copy |
![]() |
Text
RAMA_47201_08031182126010_0021077406_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
Abstract
This research uses Stainless Steel 316 as a substrate for making bone implant materials. The surface of SS316 was modified by depositing Diamond Like-Carbon (DLC), Ti and Cu using PECVD and PVD methods to improve its biocompatibility properties. Based on the test results and characterization of Vickers Hardness, Water Contact Angle (WCA), XRD, SEM-EDX and antibacterial tests using Staphylococcus aureus bacteria have been successfully carried out. The Vickers hardness test obtained optimum conditions in the DLC/Ti/Cu layer variation of 212.35 VHN. The WCA test on the DLC/Ti/Cu specimen showed a contact angle value of 145.73° with a surface energy of 1.83 dyne/cm. The results of XRD and SEM-EDX tests showed that the deposition of DLC, Ti and Cu layers on the stainless steel surface had been successfully carried out, which was indicated by the appearance of typical peaks on the diffractogram and the thickness of each variation of the DLC/Cu, Ti/Cu and DLC/Ti/Cu layers respectively of 0.74 µm; 1.11 µm; 1.51 µm and the distribution of elements on EDX. Furthermore, the antibacterial test on the Ti/Cu layer did not form an inhibition zone while on the variation of the DLC/Ti/Cu layer a symmetrical inhibition zone of 15.2 mm was formed.
Item Type: | Thesis (Undergraduate) |
---|---|
Subjects: | Q Science > QD Chemistry > QD71-142 Analytical chemistry |
Divisions: | 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1) |
Depositing User: | Putri Azzahra |
Date Deposited: | 14 Mar 2025 05:46 |
Last Modified: | 14 Mar 2025 05:46 |
URI: | http://repository.unsri.ac.id/id/eprint/168703 |
Actions (login required)
![]() |
View Item |