RIZAL, AHMAD HUSNI and Marwani, Marwani (2013) ANALISA PERFORMANSI ALAT PENUKAR KALOR JENIS SHELL AND TUBE UNTUK PENDINGIN MINYAK PELUMAS RODA GIGI MESIN FINISH MILL. Undergraduate thesis, Sriwijaya university.
![]() |
Text
RAMA_21201_03091405008.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (24MB) | Request a copy |
![]() |
Text
RAMA_21201_03091405008_0022036505_01 front ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (6MB) |
![]() |
Text
RAMA_21201_03091405008_0022036505_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (5MB) | Request a copy |
![]() |
Text
RAMA_21201_03091405008_0022036505_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (950kB) | Request a copy |
![]() |
Text
RAMA_21201_03091405008_0022036505_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (3MB) | Request a copy |
![]() |
Text
RAMA_21201_03091405008_0022036505_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (812kB) | Request a copy |
![]() |
Text
RAMA_21201_03091405008_0022036505_06 ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (349kB) | Request a copy |
![]() |
Text
RAMA_21201_03091405008_0022036505_07 lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (6MB) | Request a copy |
Abstract
Heat exchanger is one o f the main tools for heat transfering from one fluid to another fluid. Most industries which depends on this way of manufacturing always used it. Therefore, heat exchanger have the most important rules in both of production process and operate process. Advanced Research goal from this analyses performance heat exchanger is tofind effectiveness , fouling factors, and pressure drop shell and tube. As a comparison, this analyses depends on the early operational data and actual operational data from heat exchanger. Based on the result from this performance analyses, it is gained prior operational data of effectiveness score is 57%, actual operational effectiveness score is 40%, fouling factors is 0,00029°C . m2/W, pressure drop of shell is 5,71 psi, pressure drop of tube is 57 psi. From the whole Heat Exchanger performance, it is shown that the dimension of Heat Exchanger design has meet the Standard requirement. Key words : heat exchanger shell and tube, effectiveness, fouling factors, p drop.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Alat penukar kalor jenis shell and tube, nilai effektifitas , faktor pengotoran, penurunan tekanan |
Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ751-805 Miscellaneous motors and engines Including gas, gasoline, diesel engines > TJ778.B67Gas turbines handbook, manual etc. |
Divisions: | 03-Faculty of Engineering > 21201-Mechanical Engineering (S1) |
Depositing User: | Ichlasyah Aisyah |
Date Deposited: | 25 Aug 2025 03:33 |
Last Modified: | 25 Aug 2025 03:33 |
URI: | http://repository.unsri.ac.id/id/eprint/183220 |