PEMILIHAN PIPA KAPILER UNTUK MENGATASI PENURUNAN PERFORMANSI AKIBAT PENGGANTIAN REFRIGERAN PADA REFRIGERATOR/COOLING BOX

PRAMUDYA, DONI SYAFAR and Kadir, M. Zahri (2014) PEMILIHAN PIPA KAPILER UNTUK MENGATASI PENURUNAN PERFORMANSI AKIBAT PENGGANTIAN REFRIGERAN PADA REFRIGERATOR/COOLING BOX. Undergraduate thesis, Sriwijaya university.

[thumbnail of RAMA_21201_03091405011.pdf] Text
RAMA_21201_03091405011.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (62MB) | Request a copy
[thumbnail of RAMA_21201_03091405011_9990553504_01 front ref.pdf] Text
RAMA_21201_03091405011_9990553504_01 front ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (19MB)
[thumbnail of RAMA_21201_03091405011_9990553504_02.pdf] Text
RAMA_21201_03091405011_9990553504_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (5MB) | Request a copy
[thumbnail of RAMA_21201_03091405011_9990553504_03.pdf] Text
RAMA_21201_03091405011_9990553504_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (6MB) | Request a copy
[thumbnail of RAMA_21201_03091405011_9990553504_04.pdf] Text
RAMA_21201_03091405011_9990553504_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (18MB) | Request a copy
[thumbnail of RAMA_21201_03091405011_9990553504_05.pdf] Text
RAMA_21201_03091405011_9990553504_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_21201_03091405011_9990553504_06 ref.pdf] Text
RAMA_21201_03091405011_9990553504_06 ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (856kB) | Request a copy
[thumbnail of RAMA_21201_03091405011_9990553504_07 lamp.pdf] Text
RAMA_21201_03091405011_9990553504_07 lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (10MB) | Request a copy

Abstract

The utilization restriction of Chlorofluorocarbons refrigerant (CFC, HFC, etc.) that is regulated by govemment regulations, the impact of these rules cause problems on old refrigerator that usually uses Chlorofluorocarbons refrigerant (R 12, R 22, R 134a, etc.). In order to use the refrigerator, its cooling box can be replaced by its refrigerant environmentally friendly. Refrigerant replacement causes the refrigeration system performance has changed. Performance changing can be overcome by replacing/ modifying the compressor and the expansion device appropriate to the characteristics of replacement refrigerant. Compressor design changing is too complicated and expensive. One of the tools commonly used for the expansion of a small refrigerator / household is capillary tube. Therefore, a change in the dimensions of the capillary tube is preferred to compensate for the cooling system performance. The selection of the proper size capillary tube will produce optimal performance. Getting longer the capillary tube that is used in refrigerator/ cooling box produces cooling room temperature and cooling load temperature lower. Musicool MC- 134 refrigerant produces cooling room temperature and cooling load temperature lower than the HFC R-134a refrigerant. The rate of decrease of room temperature and cooling load the Musicool MC-134 refrigerant faster than the rate of temperature decrease on HFC R-134a refrigerant. Cooling room temperature (10°C) and cooling load (12°C) while the lowest achievable refrigerator/ cooling box wearing MC-134 refrigerant with the length of capillary tube is 180 cm. on Keywords: Cooling box refrigerator, musicool MC-134, HFC R-134a, temperature of cooling room, cooling load temperature, the reduction of temperature

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Refrigerator cooling box, musicool MC-134, CFC R-134a, temperatur ruang pendingin, temperatur beban pendingin, laju penurunan temperatur
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ1-1570 Mechanical engineering and machinery
Divisions: 03-Faculty of Engineering > 21201-Mechanical Engineering (S1)
Depositing User: Ichlasyah Aisyah
Date Deposited: 25 Aug 2025 03:58
Last Modified: 25 Aug 2025 03:58
URI: http://repository.unsri.ac.id/id/eprint/183222

Actions (login required)

View Item View Item