KUMALA, INDRA and Agustina, Sri (2019) ANALISA KETIDAK STABILAN TEGANGAN HASIL RANCANG BANGUN PADA GENERATOR BEDINI. Undergraduate thesis, Sriwijaya University.
Text
RAMA_20201_03041281419157.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (7MB) | Request a copy |
|
Text
RAMA_20201_03041281419157_TURNITIN.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (10MB) | Request a copy |
|
Preview |
Text
RAMA_20201_03041281419157_0018086101_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (947kB) | Preview |
Text
RAMA_20201_03041281419157_0018086101_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (625kB) | Request a copy |
|
Text
RAMA_20201_03041281419157_0018086101_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (439kB) | Request a copy |
|
Text
RAMA_20201_03041281419157_0018086101_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (438kB) | Request a copy |
|
Text
RAMA_20201_03041281419157_0018086101_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (9kB) | Request a copy |
|
Text
RAMA_20201_03041281419157_0018086101_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (163kB) | Request a copy |
|
Text
RAMA_20201_03041281419157_0018086101_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
Abstract
In today's era of electricity energy is a very important need for people's lives, such as daily lighting needs for the direct community and for the industrial community. Often people experience a power outage both occasional disruptions and Continue disorders. To suppress the risks, bedini generators are able to replace low-risk generators. Besides not producing residual gas combustion, the resulting vibration is also low so it does not cause noise that is disturbing the environment. To be able to produce electrical energy with a stable voltage and save its energy into the battery for use when the PLN power flow is disconnected. In this final task the author analyzes the voltage and current on the bedini generator which is still not as well as using the MPPT (Maximum Power Point Tracking) stabilizer. The results of the research that has been done obtained DC Output voltage of 23.94 Volt and DC charging current of 1.46 Amper. By using MPPT (Maximum Power Point Tracking) This charging time is 3 hours 30 minutes. And obtained a COP value of 2.17.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Generator, Generator Bedini, Genset, Stabilizer, MPPT (Maximum Power Point Tracking), COP (Coeficient of Performance) |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK2000-2891 Dynamoelectric machinery and auxiliaries Including generators, motors, transformers |
Divisions: | 03-Faculty of Engineering > 20201-Electrical Engineering (S1) |
Depositing User: | Users 3624 not found. |
Date Deposited: | 09 Jan 2020 07:28 |
Last Modified: | 09 Jan 2020 07:28 |
URI: | http://repository.unsri.ac.id/id/eprint/23622 |
Actions (login required)
View Item |