PERBANDINGAN HASIL ANALISIS GAS DARAH ARTERI ANTARA ALAT POINT-OF-CARE TESTING DAN LABORATORY BLOOD GAS ANALYZER

HARIS, IZA NETIASA and Liana, Phey and Hasyim, Yan Effendi (2019) PERBANDINGAN HASIL ANALISIS GAS DARAH ARTERI ANTARA ALAT POINT-OF-CARE TESTING DAN LABORATORY BLOOD GAS ANALYZER. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_11201_04011181621060.pdf] Text
RAMA_11201_04011181621060.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_11201_04011181621060_TURNITIN.pdf] Text
RAMA_11201_04011181621060_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (11MB) | Request a copy
[thumbnail of RAMA_11201_04011181621060_0003088102_0011014901_01_front_ref.pdf]
Preview
Text
RAMA_11201_04011181621060_0003088102_0011014901_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (851kB) | Preview
[thumbnail of RAMA_11201_04011181621060_0003088102_0011014901_02.pdf] Text
RAMA_11201_04011181621060_0003088102_0011014901_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (264kB) | Request a copy
[thumbnail of RAMA_11201_04011181621060_0003088102_0011014901_03.pdf] Text
RAMA_11201_04011181621060_0003088102_0011014901_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (183kB) | Request a copy
[thumbnail of RAMA_11201_04011181621060_0003088102_0011014901_04.pdf] Text
RAMA_11201_04011181621060_0003088102_0011014901_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (229kB) | Request a copy
[thumbnail of RAMA_11201_04011181621060_0003088102_0011014901_05.pdf] Text
RAMA_11201_04011181621060_0003088102_0011014901_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (103kB) | Request a copy
[thumbnail of RAMA_11201_04011181621060_0003088102_0011014901_06_ref.pdf] Text
RAMA_11201_04011181621060_0003088102_0011014901_06_ref.pdf
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (177kB) | Request a copy
[thumbnail of RAMA_11201_04011181621060_0003088102_0011014901_06_ref.pdf] Text
RAMA_11201_04011181621060_0003088102_0011014901_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (177kB) | Request a copy
[thumbnail of RAMA_11201_04011181621060_0003088102_0011014901_07_lamp.pdf] Text
RAMA_11201_04011181621060_0003088102_0011014901_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy

Abstract

Background. Blood gas analysis is one of the tests that is often used in emergency departments and intensive care units. Point-of-care testing (POCT) device facilitate medical personnel to get blood gas analysis result quickly. POCT device is compared to a laboratory blood gas analyzer to determine compatibility so the device can be used interchangeably. Method. This was an observational analytic study with a cross sectional design. The research sample is data from the analysis of patient's arterial blood gas analyzed using POCT i-STAT and Nova pHox Ultra blood gas. The parameters tested were pH, pCO2, and pO2 with 42 samples. Data were analyzed using the Shapiro-Wilk normality test, the Spearman correlation test, the Mann-Whitney comparison test and the Bland-Altman agreement test. Results. Test have shown that there was a significant correlation (p value <0.05) with a very strong relationship strength (r> 0.08). There was no significant difference between blood gas analysis result of the two devices (p value> 0.05). The agreement test have shown >95% of plots are within the acceptable limit with a moderate correlation strength (concordance correlation coefficient 0.90-0.95). The mean bias from the results of blood gas analysis between the two parameters is not clinically significant. Conclusion. There was no difference in the results of arterial blood gas analysis between POCT i-STAT and Nova pHox Ultra blood gas analyzer so that the two devices can be used interchangeably.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Komparasi Metode, Point-of-Care Testing, Blood Gas Analyzer
Subjects: R Medicine > RB Pathology > RB37-56.5 Clinical pathology. Laboratory technique
Divisions: 04-Faculty of Medicine > 11201-Medicine (S1)
Depositing User: Users 4193 not found.
Date Deposited: 13 Jan 2020 05:03
Last Modified: 14 Jan 2020 02:47
URI: http://repository.unsri.ac.id/id/eprint/23826

Actions (login required)

View Item View Item