H, GUSTIA ARYANTI and Suheryanto, Suheryanto and Syarif, Nirwan (2020) ANALISIS SPESIASI ION TIMBAL (II) DAN ION TIMBAL (IV) DI AIR LINDI MENGGUNAKAN METODE POTENSIOMETRI. Undergraduate thesis, Sriwijaya University.
Text
RAMA_47201_08031181520011.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
|
Text
RAMA_47201_08031181520011_TURNITIN.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (6MB) | Request a copy |
|
Preview |
Text
RAMA_47201_08031181520011_0025066004_0001107001_01_front_ref.pdf Download (829kB) | Preview |
Text
RAMA_47201_08031181520011_0025066004_0001107001_02.pdf - Accepted Version Restricted to Repository staff only Download (373kB) | Request a copy |
|
Text
RAMA_47201_08031181520011_0025066004_0001107001_03.pdf - Accepted Version Restricted to Repository staff only Download (341kB) | Request a copy |
|
Text
RAMA_47201_08031181520011_0025066004_0001107001_04.pdf - Accepted Version Restricted to Repository staff only Download (347kB) | Request a copy |
|
Text
RAMA_47201_08031181520011_0025066004_0001107001_05.pdf - Accepted Version Restricted to Repository staff only Download (147kB) | Request a copy |
|
Text
RAMA_47201_08031181520011_0025066004_0001107001_06_ref.pdf - Accepted Version Restricted to Repository staff only Download (283kB) | Request a copy |
|
Text
RAMA_47201_08031181520011_0025066004_0001107001_07_lamp.pdf - Accepted Version Restricted to Repository staff only Download (834kB) | Request a copy |
Abstract
The analysis of speciation of Pb2+ and Pb4+ ions in leachatewith potentiometric method of cell concentrationhas been done. The aims of this research was to determined for optimum conditions from speciation analysis of Pb2+ and Pb4+ ions in variation condition such as pH and temperature, validation methods and amount of Pb2+ and Pb4+ ions in leachate water also carried out in leachate water. Thismethods have a simple circuit, consisting of the anode and cathode connected by a salt bridge and multimeter. The anode and cathode contain the same Pb metal electrodes. Electrolyte Pb2+and Pb4+ ions solution with different concentration. Potentiometric methods of cell type of concentration for speciation of Pb2+ and Pb4+ ions have an optimum condition at pH 5 and temperature 30°C. Based on a calibration curve, Pb2+ ions has a regression y = 12,974x with line equation R = 0,998. Pb4+ ion has a regression y = 32,703x with line equation R = 0,999. LoD and LoQintrument of 0,21 mg/L. The test showed that the accuracy of the method is very high because the % RSD obtained 0,3 % with an average accuracy 94,32 %. The condition of Pb2+ ions in leachate water was obtained at 0,31 mg/L to 0,46 mg/L with avarage 0,38 mg/L. As for Pb4+ ions in leachate was obtained at 0,55 mg/L to 0,61 mg/L with average 0,59 mg/L. The condition of Pb2+ and Pb4+ ions obtained have exceeded the environmental standards set by the regulatory environment minister (0,1 mg/L).
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Speciation of Pb2+ions and Pb4+ ions, Leachate, Potentiometric cellconcentration, Validation |
Subjects: | Q Science > QD Chemistry > QD71-142 Analytical chemistry |
Divisions: | 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1) |
Depositing User: | Users 5091 not found. |
Date Deposited: | 31 Jan 2020 07:37 |
Last Modified: | 31 Jan 2020 07:37 |
URI: | http://repository.unsri.ac.id/id/eprint/26637 |
Actions (login required)
View Item |