FAKTOR RISIKO KELUHAN IRITASI MATA PADA PENGGUNA KOLAM RENANG LUMBAN TIRTA PALEMBANG TAHUN 2019

KALSUM, BAWIYAH UMI and Septiawati, Dwi (2019) FAKTOR RISIKO KELUHAN IRITASI MATA PADA PENGGUNA KOLAM RENANG LUMBAN TIRTA PALEMBANG TAHUN 2019. Undergraduate thesis, Sriwijaya university.

[thumbnail of RAMA_13201_10011181520264.pdf] Text
RAMA_13201_10011181520264.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_13201_10011181520264_TURNITIN.pdf] Text
RAMA_13201_10011181520264_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (10MB) | Request a copy
[thumbnail of RAMA_13201_10011181520264_8886630017_01_front_ref.pdf] Text
RAMA_13201_10011181520264_8886630017_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_13201_10011181520264_8886630017_02.pdf] Text
RAMA_13201_10011181520264_8886630017_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (275kB) | Request a copy
[thumbnail of RAMA_13201_10011181520264_8886630017_03.pdf] Text
RAMA_13201_10011181520264_8886630017_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (108kB) | Request a copy
[thumbnail of RAMA_13201_10011181520264_8886630017_04.pdf] Text
RAMA_13201_10011181520264_8886630017_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (309kB) | Request a copy
[thumbnail of RAMA_13201_10011181520264_8886630017_05.pdf] Text
RAMA_13201_10011181520264_8886630017_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (235kB) | Request a copy
[thumbnail of RAMA_13201_10011181520264_8886630017_06.pdf] Text
RAMA_13201_10011181520264_8886630017_06.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (180kB) | Request a copy
[thumbnail of RAMA_13201_10011181520264_8886630017_07.pdf] Text
RAMA_13201_10011181520264_8886630017_07.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (88kB) | Request a copy
[thumbnail of RAMA_13201_10011181520264_8886630017_06_ref.pdf] Text
RAMA_13201_10011181520264_8886630017_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (162kB) | Request a copy
[thumbnail of RAMA_13201_10011181520264_8886630017_07_lamp.pdf] Text
RAMA_13201_10011181520264_8886630017_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy

Abstract

Pool using chlorination as a sanitary method for keeping the pool water quality to be maintained. According to PERMENKES RI No. 32 2017 levels of residualchlorine and pH are allowed in the pool water is (1-1,5)mg/L and 7-7,8.as a disinfectant, chlorine residual and pH in water supply deliberately maintained. The purpose of this research is to analyze correlation of risk factors to eye irritation complaints in users of the Lumban Tirta Palembang swimming pool. This study applied analythic with cross sectional design.The respondent population used was all daily visitors at the Lumban Tirta Palembang swimming pool. The samples were 61 swimming pool users. They were taken by incidental random sampling technique. The data were analyzed univariate and bivariate by using chi square test. The data was presented in table form and naration to interpret it. The results of this research 53 users (86.9%)had eye irritation. The rest of chlorine waseligible on regulation of minister Health No. 416 year 1990 with 0.2-0.5 mg / L. The results of bivariate analysis showed that there were significant correlation between chlorine residual content and eye irritation , with p value (0.017) <0.05 and PR 1,286 (95% CI: 1.080-1.531). There were significant correlation between pH of pond water and eye irritation complaints, with a p value (0.002) <0.05 and PR 1.644 (95% CI: 1.016-2,662). There was no significant correlation between the durationand the use of swimming goggleswith eye irritation complaint.The conclusion of this study shows that exposure to residual chlorine levels and pH of swimming pool water that does not meet the requirements based onPERMENKES RI No. 32 2017 users experience eye irritation complaints.Swimming pool users were appealed to keep themselves celan and quality of pond water to avoid eye irritation.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: KELUHAN IRITASI MATA,SISA KHLORIN, PH,KOLAM RENANG
Subjects: R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine
Divisions: 10-Faculty of Public Health > 13201-Public Health (S1)
Depositing User: Users 390 not found.
Date Deposited: 07 Aug 2019 07:00
Last Modified: 07 Aug 2019 07:00
URI: http://repository.unsri.ac.id/id/eprint/2786

Actions (login required)

View Item View Item