HUBUNGAN HYGIENE SANITASI DEPOT AIR MINUM (DAM) DENGAN KEBERADAAN BAKTERI COLIFORM PADA AIR MINUM DI KECAMATAN MUARA ENIM

SANDRA, MARYLIN and Septiawati, Dwi (2020) HUBUNGAN HYGIENE SANITASI DEPOT AIR MINUM (DAM) DENGAN KEBERADAAN BAKTERI COLIFORM PADA AIR MINUM DI KECAMATAN MUARA ENIM. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_13201_10011381821001.pdf] Text
RAMA_13201_10011381821001.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_13201_10011381821001_TURNITIN.pdf] Text
RAMA_13201_10011381821001_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (12MB) | Request a copy
[thumbnail of RAMA_13201_10011381821001_8886630017_01_front_ref.pdf]
Preview
Text
RAMA_13201_10011381821001_8886630017_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (951kB) | Preview
[thumbnail of RAMA_13201_10011381821001_8886630017_02.pdf] Text
RAMA_13201_10011381821001_8886630017_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (416kB) | Request a copy
[thumbnail of RAMA_13201_10011381821001_8886630017_03.pdf] Text
RAMA_13201_10011381821001_8886630017_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (326kB) | Request a copy
[thumbnail of RAMA_13201_10011381821001_8886630017_04.pdf] Text
RAMA_13201_10011381821001_8886630017_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (328kB) | Request a copy
[thumbnail of RAMA_13201_10011381821001_8886630017_05.pdf] Text
RAMA_13201_10011381821001_8886630017_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (456kB) | Request a copy
[thumbnail of RAMA_13201_10011381821001_8886630017_06.pdf] Text
RAMA_13201_10011381821001_8886630017_06.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (522kB) | Request a copy
[thumbnail of RAMA_13201_10011381821001_8886630017_07.pdf] Text
RAMA_13201_10011381821001_8886630017_07.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (473kB) | Request a copy
[thumbnail of RAMA_13201_10011381821001_8886630017_06_ref.pdf] Text
RAMA_13201_10011381821001_8886630017_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (301kB) | Request a copy
[thumbnail of RAMA_13201_10011381821001_8886630017_07_lamp.pdf] Text
RAMA_13201_10011381821001_8886630017_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy

Abstract

The number of DWD in Muara Enim District has increased rapidly in the last 2 years, but this increase has not been accompanied by supervision of hygiene sanitation, so it is feared that it will have a negative impact on the community, namely the presence of Coliform bacteria in its production drinking water. This study aims to analyze the relationship between DWD hygiene sanitation and the presence of Coliform bacteria in drinking water. The design used is a cross-sectional study design. The samples examined were 44 depots, taken from all DWDs in Muara Enim District which were recorded at the Health Office of Muara Enim Regency. Data were collected using questionnaires, observation and laboratory tests. Data analysis was performed univariate and bivariate using the chi square test. Of the 44 DWDs examined, 72% contained Coliform bacteria, the results of the analysis showed a relationship between the presence of Coliform bacteria with hygiene sanitation (p-value = 0.047 and PR = 1.552) and equipment sanitation (p-value = 0.008 and PR = 1.667). The conclusion of this study is that the effectiveness of the disinfection device is an important point to pay attention to because it has a high risk of coliform bacteria. It is recommended that drinking water depot owners routinely check the effectiveness of the disinfection device.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Bakteri Coliform, Depot Air Minum, Hygiene Sanitasi
Subjects: R Medicine > RA Public aspects of medicine > RA0421 Public health. Hygiene. Preventive Medicine
Divisions: 10-Faculty of Public Health > 13201-Public Health (S1)
Depositing User: Users 8754 not found.
Date Deposited: 06 Nov 2020 03:05
Last Modified: 06 Nov 2020 03:05
URI: http://repository.unsri.ac.id/id/eprint/37325

Actions (login required)

View Item View Item