EMERGENCY RESPONSE PLAN PADA LABORATORIUM TEKNIK KIMIA UNIVERSITAS SRIWIJAYA

MONICA, KARINA and Camelia, Anita (2020) EMERGENCY RESPONSE PLAN PADA LABORATORIUM TEKNIK KIMIA UNIVERSITAS SRIWIJAYA. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_13201_10011281621072.pdf] Text
RAMA_13201_10011281621072.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_13201_10011281621072_TURNITIN.pdf] Text
RAMA_13201_10011281621072_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (25MB) | Request a copy
[thumbnail of RAMA_13201_10011281621072_0018018007_01_front_ref.pdf]
Preview
Text
RAMA_13201_10011281621072_0018018007_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (492kB) | Preview
[thumbnail of RAMA_13201_10011281621072_0018018007_02.pdf] Text
RAMA_13201_10011281621072_0018018007_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (469kB) | Request a copy
[thumbnail of RAMA_13201_10011281621072_0018018007_03.pdf] Text
RAMA_13201_10011281621072_0018018007_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (19kB) | Request a copy
[thumbnail of RAMA_13201_10011281621072_0018018007_04.pdf] Text
RAMA_13201_10011281621072_0018018007_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (138kB) | Request a copy
[thumbnail of RAMA_13201_10011281621072_0018018007_05.pdf] Text
RAMA_13201_10011281621072_0018018007_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (890kB) | Request a copy
[thumbnail of RAMA_13201_10011281621072_0018018007_06.pdf] Text
RAMA_13201_10011281621072_0018018007_06.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (346kB) | Request a copy
[thumbnail of RAMA_13201_10011281621072_0018018007_06_ref.pdf] Text
RAMA_13201_10011281621072_0018018007_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (385kB) | Request a copy
[thumbnail of RAMA_13201_10011281621072_0018018007_07.pdf] Text
RAMA_13201_10011281621072_0018018007_07.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (113kB) | Request a copy
[thumbnail of RAMA_13201_10011281621072_0018018007_07_lamp.pdf] Text
RAMA_13201_10011281621072_0018018007_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (827kB) | Request a copy

Abstract

Chemical Engineering Laboratory of Sriwijaya University is one of the buildings that stores flammable and oxidized chemicals and electrical equipment that has a risk of fire. Emergency response plan in the form of means-escape facilities and emergency response procedures can prevent fatalities when fire occurs. Design used in this research is descriptive with qualitative method. Informants selected by purposive sampling. The number of informants 7 people with the details of one person administrator of Chemical Engineering Laboratory, 3 laboratory analysts, and 3 laboratory users. This study aims to calculate the evacuation time based on the SPFE 3rd Handbook of Fire Protection Engineering 2002 and make analysis in accordance with SNI 03-1746-2000, SNI 03-1745-2000, SNI 03-6574-2001, PermenPU No. 20 of 2009 and NFPA 101. Exit doors and stairs are suitably qualified with SNI 03-1746-2000 but have not fulfilled the required number of doors and stairs, the exit acess suitably qualified with SNI 03-6574-2001, there is no exit sign, assembly point is located behind the chemical engineering department building suitably qualified NFPA 101, no written policy regarding emergency response procedures and the time needed for the evacuation to meeting point for 260.8 seconds or 4.3 minutes and has not met the maximum time standard for evacuation according to NFPA 101. Additional exits door are needed on the laboratory and additional stairs on the second floor, put exit sign at every exit access from the laboratory such as on doors and corridor intersections, make emergency response procedures in written form that are placed in each laboratory room, and form a special team to handle fire emergencies.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: emergency response plan, means escape, fire
Subjects: K Law > K Law (General) > K3566-3578 Public health
Divisions: 10-Faculty of Public Health > 13201-Public Health (S1)
Depositing User: Users 8917 not found.
Date Deposited: 27 Nov 2020 01:29
Last Modified: 27 Nov 2020 01:29
URI: http://repository.unsri.ac.id/id/eprint/37988

Actions (login required)

View Item View Item