JAYANTI, DEWI and Suheryanto, Suheryanto and Fanani, Zainal (2018) APLIKASI METODE POTENSIOMETRI UNTUK ANALISIS LOGAM TEMBAGA (Cu) DALAM AIR LINDI. Undergraduate thesis, Sriwijaya University.
Preview |
Text
RAMA_47201_08031181419008_0025066004_0021086701_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (389kB) | Preview |
Text
RAMA_47201_08031181419008_0025066004_0021086701_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (267kB) | Request a copy |
|
Text
RAMA_47201_08031181419008_0025066004_0021086701_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (255kB) | Request a copy |
|
Text
RAMA_47201_08031181419008_0025066004_0021086701_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (245kB) | Request a copy |
|
Text
RAMA_47201_08031181419008_0025066004_0021086701_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (85kB) | Request a copy |
|
Text
RAMA_47201_08031181419008_0025066004_0021086701_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (118kB) | Request a copy |
|
Text
RAMA_47201_08031181419008_0025066004_0021086701_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (360kB) | Request a copy |
Abstract
Potentiometry is part of the electrochemical analysis technique, where there was a potential measurement of two electrodes at a current equal to zero. Potentiometric methods can determine the activity coefficients, pH value, dissociation constants and product solubility, standard affinity and chemical reactions. In this research was done analysis of copper metal in leachate water taken from TPA Sukawinatan Palembang in five locations such as pond leachate 1 to pond leachate 5. The potentiometric method must be validated first and determined the optimum conditions such as temperature, pH and the effect of foreign ion. This method have a correlation coefficient of 0.9997 and linear region in the concentration range 1x10-3 - 1x10-5 mol/L. The accuracy of this potentiometric method was very good because the percentage of RSD produced was 0.6% with an average accuracy of 95.35%. The detection limit (LoD) of the measurable method was 1.085x10-6 mol/L with LoQ 1.313x10-6 mol/L and the LoD instrument 1.217x10-6 mol/L and LoQ 1.560x10-6 mol L-1. In addition, this method has a high the selectivity coefficient is -3.7 and it has uncertainty of measurement 9.7x10-7 ± 1,282x10-6 mol/L to 9.12x10-5 ± 3.5x10-5 mol/L. Potentiometric method of cell type of concentration has an optimum condition at pH 5 and temperature 30˚C. The conditions of copper in leachate water ranged from 0.588 to 55.3 mg/L. Potentiometric methods based on concentration cells have good validation results and can be used to determine the metal concentration in environment.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | potentiometric, copper, leachate, concentration cell, validation |
Subjects: | Q Science > QD Chemistry > QD1-999 Chemistry Q Science > QD Chemistry > QD146-197 Inorganic chemistry Q Science > QD Chemistry > QD625-655 Radiation chemistry |
Divisions: | 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1) |
Depositing User: | Mrs Dies Meirita Sari |
Date Deposited: | 12 Aug 2019 04:28 |
Last Modified: | 12 Aug 2019 04:28 |
URI: | http://repository.unsri.ac.id/id/eprint/4118 |
Actions (login required)
View Item |