UJI KINERJA MESIN PENGERING MAGGOT (HERMETIA ILLUCENS) DENGAN MENGGUNAKAN HEATER LISTRIK

PUTRI, MUTIARA and Kuncoro, Endo Argo and Tunggal, Tri (2021) UJI KINERJA MESIN PENGERING MAGGOT (HERMETIA ILLUCENS) DENGAN MENGGUNAKAN HEATER LISTRIK. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_41201_05021281722025.pdf] Text
RAMA_41201_05021281722025.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_41201_05021281722025_TURNITIN.pdf] Text
RAMA_41201_05021281722025_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (4MB) | Request a copy
[thumbnail of RAMA_41201_05021281722025-0005076105_0029106201_01_front_ref.pdf]
Preview
Text
RAMA_41201_05021281722025-0005076105_0029106201_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Preview
[thumbnail of RAMA_41201_05021281722025_0005076105_0029106201_02.pdf] Text
RAMA_41201_05021281722025_0005076105_0029106201_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_41201_05021281722025_0005076105_0029106201_03.pdf] Text
RAMA_41201_05021281722025_0005076105_0029106201_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (965kB) | Request a copy
[thumbnail of RAMA_41201_05021281722025_0005076105_0029106201_04.pdf] Text
RAMA_41201_05021281722025_0005076105_0029106201_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (937kB) | Request a copy
[thumbnail of RAMA_41201_05021281722025_0005076105_0029106201_05.pdf] Text
RAMA_41201_05021281722025_0005076105_0029106201_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (898kB) | Request a copy
[thumbnail of RAMA_41201_05021281722025_0005076105_0029106201_06_ref.pdf] Text
RAMA_41201_05021281722025_0005076105_0029106201_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_41201_05021281722025_0005076105_0029106201_07_lamp.pdf] Text
RAMA_41201_05021281722025_0005076105_0029106201_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy

Abstract

This research was aimed to find out the efficiency of the performance of Maggot dryer machine to drying result. This research has been conducted from January 2021 to March 2021 at the Laboratory of Agricultural Machinery and workshop, Faculty of Agriculture, Sriwijaya University, Indralaya, South Sumatera. The method used was Factorial Randomized Block Design (RAFK) with two research factors, namely the drying temperature (A) and the rotation of blower cylinder (B) with three levels of treatment and each treatment combination was repeated three times. The parameters of this research are drying rate (g/hour), water content of material (%), consumption of electrical energy (kWh), and drying efficiency (%). The results of this research showed that the treatment of the drying temperature had a real different on the drying rate, water content of material, consumption of electrical energy, and drying efficiency. The treatment of the rotation of blower cylinder had a real different on the drying rate, water content of material, consumption of electrical energy, and unreal effect on the drying efficiency. The highest drying rate value found in treatment of A3B1 which is 8.80 g/hour, the lowest water content of material value found in treatment A1B3 which is 9.04%, the highest consumption of electrical energy value found in treatment A3B3 which is 0.32 kWh, the highest drying efficiency value found in treatment A1B1 which is 31.10%. Drying efficiency is influenced by water content of material, the higher water content of material, the lower drying efficiency. Drying efficiency is also influenced by the consumption of electrical energy, the higher consumption of electrical energy, the lower drying efficiency.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Maggot, Mesin pengering, Uji kinerja
Subjects: S Agriculture > S Agriculture (General) > S1-(972) Agriculture (General)
S Agriculture > S Agriculture (General) > S548-548.6 Historic farms
S Agriculture > S Agriculture (General) > S671-760.5 Farm machinery and farm engineering
Divisions: 05-Faculty of Agriculture > 41201-Agricultural Engineering (S1)
Depositing User: Mutiara Putri
Date Deposited: 27 Jul 2021 04:31
Last Modified: 27 Jul 2021 04:31
URI: http://repository.unsri.ac.id/id/eprint/50541

Actions (login required)

View Item View Item