ANALISA KONFIGURASI DINDING GESER SEBAGAI DESAIN ALTERNATIF STUDI KASUS GEDUNG MAPOLDA PROVINSI SUMATERA SELATAN

GUNAWAN, JOSE ANDRE and Hanafiah, Hanafiah and Nurjannah, Siti Aisyah (2021) ANALISA KONFIGURASI DINDING GESER SEBAGAI DESAIN ALTERNATIF STUDI KASUS GEDUNG MAPOLDA PROVINSI SUMATERA SELATAN. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_22201_030113811722158.pdf] Text
RAMA_22201_030113811722158.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (21MB) | Request a copy
[thumbnail of RAMA_22201_03011381722158_TURNITIN.pdf] Text
RAMA_22201_03011381722158_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (9MB) | Request a copy
[thumbnail of RAMA_22201_03011381722158_0014035601_8884960018_01_front_ref.pdf]
Preview
Text
RAMA_22201_03011381722158_0014035601_8884960018_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Preview
[thumbnail of RAMA_22201_03011381722158_0014035601_8884960018_02.pdf] Text
RAMA_22201_03011381722158_0014035601_8884960018_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (896kB) | Request a copy
[thumbnail of RAMA_22201_03011381722158_0014035601_8884960018_03.pdf] Text
RAMA_22201_03011381722158_0014035601_8884960018_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_22201_03011381722158_0014035601_8884960018_04.pdf] Text
RAMA_22201_03011381722158_0014035601_8884960018_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_22201_03011381722158_0014035601_8884960018_05.pdf] Text
RAMA_22201_03011381722158_0014035601_8884960018_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (153kB) | Request a copy
[thumbnail of RAMA_22201_03011381722158_0014035601_8884960018_06_ref.pdf] Text
RAMA_22201_03011381722158_0014035601_8884960018_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (149kB) | Request a copy
[thumbnail of RAMA_22201_03011381722158_0014035601_8884960018_07_lamp.pdf] Text
RAMA_22201_03011381722158_0014035601_8884960018_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (15MB) | Request a copy

Abstract

Planning and designing earthquake resistant reinforced concrete high rise building in Indonesia are regulated in SNI 1726-2019 and SNI 2847-2019. Systems that are used to withstand earthquake forces in buildings with high levels are Moment Resistant Frame System (SRPM), Structural Wall System (SDS), and Dual System. A case study which is Mapolda Provinsi Sumatera Selatan Building have 8 stories that are planned and designed with Special Momen resistant Frame System (SRPMK) based on the location of the building which is in Palembang. There are 2 types of alternate design that has been analyzed using Dual System. The difference between 2 types of alternate design is on the location of the shear wall. First type of alternate design is using shear wall at the corner of the building. Second type of alternate design using shear wall on the side of the building. All type of the building analyzed using software SAP2000. There are some safety trouble during the analysis process of the existing building, therefore in planning the alternative design of the columns and beams the size is changed to suit the earthquake load that occurs in the building. Column dimensions were changed to 90 x 90 cm and 70 x 70 cm, and the beam dimensions were fixed but the beam reinforcement was added to strengthen the structure. The result of the performance analysis in story drift is alternative design type 1 have the smallest value compare to the existing and alternatif design type 2. In conclusion, alternate design modal using shear walls and enlarging column dimensions results is a safer design than the existing model.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Sistem Ganda, SAP2000, simpangan antar lantai, konfigurasi dinding geser
Subjects: T Technology > TH Building construction > TH1-9745 Building construction
T Technology > TH Building construction > TH2025-3000 Details in building design and construction Including walls, roofs
Divisions: 03-Faculty of Engineering > 22201-Civil Engineering (S1)
Depositing User: Mr. Jose Andre Gunawan
Date Deposited: 04 Aug 2021 03:20
Last Modified: 04 Aug 2021 03:20
URI: http://repository.unsri.ac.id/id/eprint/51444

Actions (login required)

View Item View Item