ANALISIS PERBANDINGAN KONFIGURASI BALOK ANAK PADA STRUKTUR GEDUNG MAPOLDA PROVINSI SUMATERA SELATAN

WINATA, ENRICO and Hanafiah, Hanafiah and Nurjannah, Siti Aisyah (2021) ANALISIS PERBANDINGAN KONFIGURASI BALOK ANAK PADA STRUKTUR GEDUNG MAPOLDA PROVINSI SUMATERA SELATAN. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_22201_03011381722132.pdf] Text
RAMA_22201_03011381722132.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (17MB) | Request a copy
[thumbnail of RAMA_22201_03011381722132_TURNITIN.pdf] Text
RAMA_22201_03011381722132_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (10MB) | Request a copy
[thumbnail of RAMA_22201_03011381722132_0014035601_8884960018_01_front_ref.pdf]
Preview
Text
RAMA_22201_03011381722132_0014035601_8884960018_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Preview
[thumbnail of RAMA_22201_03011381722132_0014035601_8884960018_02.pdf] Text
RAMA_22201_03011381722132_0014035601_8884960018_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (957kB) | Request a copy
[thumbnail of RAMA_22201_03011381722132_0014035601_8884960018_03.pdf] Text
RAMA_22201_03011381722132_0014035601_8884960018_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (680kB) | Request a copy
[thumbnail of RAMA_22201_03011381722132_0014035601_8884960018_04.pdf] Text
RAMA_22201_03011381722132_0014035601_8884960018_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (987kB) | Request a copy
[thumbnail of RAMA_22201_03011381722132_0014035601_8884960018_05.pdf] Text
RAMA_22201_03011381722132_0014035601_8884960018_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (102kB) | Request a copy
[thumbnail of RAMA_22201_03011381722132_0014035601_8884960018_06_ref.pdf] Text
RAMA_22201_03011381722132_0014035601_8884960018_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (205kB) | Request a copy
[thumbnail of RAMA_22201_03011381722132_0014035601_8884960018_07_lamp.pdf] Text
RAMA_22201_03011381722132_0014035601_8884960018_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (9MB) | Request a copy

Abstract

This study analyzed the structure of Mapolda South Sumatera building which has seven stories reinforced concrete structure building with one roof floor. This building has a total height of 33 meters, a total length of 65 meters and a total width 40 meters. In this analysis there are three types modeling that is existing model, alternative 1 model and alternative 2 model. The Mapolda South Sumatera building structure uses a special moment frame system. In each modeling, design capacity check and structure behavior are carried out in the form of beam deflection, slab deflection and story drift. In model 1 (existing) it was found that the design checks on several elements of the column were prone to failure. So that structural changes were made by reducing the number of beams so that the load carried by the structural elements especially column and main beam could be reduced (Modeling 2). As a result, the structural elements that are prone to failure are significantly reduced but there are still some elements of the column on the ground floor and the column that support the stairs that have the potential to experience structural failure. Therefore, modeling is continued with alternative model 2 (Modeling 3) by enlarging the dimension of the column which have potential to experince structural failure to 90x90 cm and the result is that the structure is declared safe from the capacity design check. The alternative design 2 is able to produce a structure with a maximum deflection and deviation which is smaller than existing model. Modeling and analysis of structural performance is carried out using the SAP 2000 v14.1.0 program.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Defleksi, simpangan antar lantai, sistem rangka pemikul momen khusus
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA630-695 Structural engineering (General) > TA647.H356 Structural dynamics-Vibration-Shock (Mechanics)- Airframes--Testing Buildings--Earthquake effects--Data processing--Handbooks, manuals, etc
T Technology > TH Building construction
Divisions: 03-Faculty of Engineering > 22201-Civil Engineering (S1)
Depositing User: ENRICO WINATA
Date Deposited: 04 Aug 2021 08:06
Last Modified: 04 Aug 2021 08:06
URI: http://repository.unsri.ac.id/id/eprint/51450

Actions (login required)

View Item View Item