PENGARUH KUAT ARUS DAN WAKTU ELEKTROKOAGULASI TERHADAP PENURUNAN PH, TSS, TDS, MINYAK DAN COD DALAM POME

APRIANI, DEWI ANANDA and Parwiyanti, Parwiyanti and Yudono, Bambang (2021) PENGARUH KUAT ARUS DAN WAKTU ELEKTROKOAGULASI TERHADAP PENURUNAN PH, TSS, TDS, MINYAK DAN COD DALAM POME. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_41231_05031181722006.pdf] Text
RAMA_41231_05031181722006.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_41231_05031181722006_0025076001_ 0007026105_01_front_ref.pdf]
Preview
Text
RAMA_41231_05031181722006_0025076001_ 0007026105_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (655kB) | Preview
[thumbnail of RAMA_41231_05031181722006_0025076001_0007026105_02.pdf] Text
RAMA_41231_05031181722006_0025076001_0007026105_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (157kB) | Request a copy
[thumbnail of RAMA_41231_05031181722006_0025076001_0007026105_03.pdf] Text
RAMA_41231_05031181722006_0025076001_0007026105_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (183kB) | Request a copy
[thumbnail of RAMA_41231_05031181722006_0025076001_0007026105_04.pdf] Text
RAMA_41231_05031181722006_0025076001_0007026105_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (316kB) | Request a copy
[thumbnail of RAMA_41231_05031181722006_0025076001_0007026105_05.pdf] Text
RAMA_41231_05031181722006_0025076001_0007026105_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (29kB) | Request a copy
[thumbnail of RAMA_41231_05031181722006_0025076001_0007026105_06_ref.pdf] Text
RAMA_41231_05031181722006_0025076001_0007026105_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (120kB) | Request a copy
[thumbnail of RAMA_41231_05031181722006_0025076001_0007026105_07_lamp.pdf] Text
RAMA_41231_05031181722006_0025076001_0007026105_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_41231_05031181722006_TURNITIN.pdf] Text
RAMA_41231_05031181722006_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (4MB) | Request a copy

Abstract

The objective of this research was to determine the effect of using aluminum electrodes on the electrocoagulation process with different amount of currents and operating time on decreasing pH, TSS, TDS, oil and COD levels in POME. This study used a Completely Randomized Factorial Design (RALF) with two treatment factors and was repeated 3 times. The first factor is the amount of currents (10 Ampere, 40 Ampere, 70 Ampere and 100 Ampere) and the second factor is operating time (1 hour, 2 hours, 3 hours, 4 hours and 5 hours). Parameters observed were pH, levels of TSS, TDS and oil. The results showed that amount of currents, operating time and the interaction between the two had a significant effect on pH, TSS, TDS and oil levels. The best treatment is selected based on a value that is close to the quality standard of Palm Oil Effluent in accordance with the Regulation of the Ministry of the Environment of the Republic of Indonesia number 5 of 2014 concerning the quality standard of waste water. Treatment with a amount of currents of 70 Amperes and an operating time of 5 hours was chosen as the best treatment with efficiency in reducing pH, TSS, TDS, oil and COD levels of 4,9%, 91.7%, 16.2%, 93.8% and 86,7% respectively. Keyword: POME, Electrocoagulation, Amount of Currents, Operating Time, Alumunium.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: POME, Elektrokoagulasi, Kuat Arus, Waktu Operasi, Alumunium
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD896-899 Industrial and factory wastes
Divisions: 05-Faculty of Agriculture > 41231-Agricultural Product Technology (S1)
Depositing User: Users 16695 not found.
Date Deposited: 09 Dec 2021 01:46
Last Modified: 09 Dec 2021 01:46
URI: http://repository.unsri.ac.id/id/eprint/59045

Actions (login required)

View Item View Item