MEILINA, LUCIA and Suheryanto, Suheryanto and Fanani, Zainal (2018) PENGGUNAAN METODE POTENSIOMETRI UNTUK PENENTUAN LOGAM TIMBAL (Pb) DALAM KOLAM PENGOLAHAN LINDI DI TPA SUKAWINATAN PALEMBANG. Undergraduate thesis, Sriwijaya University.
Preview |
Text
RAMA_47201_08031181419016_0025066004_0021086701_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (1MB) | Preview |
Text
RAMA_47201_08031181419016_0025066004_0021086701_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (685kB) | Request a copy |
|
Text
RAMA_47201_08031181419016_0025066004_0021086701_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (606kB) | Request a copy |
|
Text
RAMA_47201_08031181419016_0025066004_0021086701_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (373kB) | Request a copy |
|
Text
RAMA_47201_08031181419016_0025066004_0021086701_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (178kB) | Request a copy |
|
Text
RAMA_47201_08031181419016_0025066004_0021086701_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (83kB) | Request a copy |
|
Text
RAMA_47201_08031181419016_0025066004_0021086701_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (644kB) | Request a copy |
Abstract
The analysis of lead metal (Pb) in leachate treatment pond at TPA Sukawinatan Palembang using potentiometric method with comparative electrode Ag/AgCl. The purpose of this study was to apply potentiometric methods to determine heavy metals contained in water and to determine lead metals in leachate water. Leachate samples were taken from 5 locations, namely leachate treatment ponds 1,2,3,4 and 5. The concentrations of lead metal in leachate treatment ponds were 1,2,3,4 and 5 respectively 37 mg/L, 5.8 mg/L, 0.66 mg/L, 0.33 mg/L, 0.14 mg/L. the value exceed the environmental quality standard according to the environment minister (0.1 mg/L).The analysis of lead in leachate treatment pond using potentiometric method obtained with precision 0.21%, the result indicates that this method has a good accuracy because its fulfill the requirement value % RSD <2%. And Accuracy of 97.23%. Measurement uncertainty of 3.79 ± 4.34 mg/L, 0.60 ± 1.15x10-5 mg/L, 0.06 ± 1.73x10-7 mg/L, 0.03 ± 3.38x10-8 mg/L 0.01 ± 6.39x10-9 mg/L.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Lead, leachate water, potentiometry, comparative electrode |
Subjects: | Q Science > QD Chemistry > QD1-65 General. Including alchemy |
Divisions: | 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1) |
Depositing User: | Mrs Kharisma Afrianti |
Date Deposited: | 02 Sep 2019 08:40 |
Last Modified: | 02 Sep 2019 08:40 |
URI: | http://repository.unsri.ac.id/id/eprint/6069 |
Actions (login required)
View Item |