FAKTOR YANG BERHUBUNGAN DENGAN KELUHAN PENDENGARAN NON AUDITORY EFFECT PEKERJA AREA MESIN DI PT PLN (PERSERO) UNIT LAYANAN PUSAT LISTRIK INDRALAYA

THERE, CHELSEA DEKA and Novrikasari, Novrikasari (2022) FAKTOR YANG BERHUBUNGAN DENGAN KELUHAN PENDENGARAN NON AUDITORY EFFECT PEKERJA AREA MESIN DI PT PLN (PERSERO) UNIT LAYANAN PUSAT LISTRIK INDRALAYA. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_13201_10011181722095.pdf] Text
RAMA_13201_10011181722095.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_13201_10011181722095_TURNITIN.pdf] Text
RAMA_13201_10011181722095_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (11MB) | Request a copy
[thumbnail of RAMA_13201_10011181722095__0021117801_01_front_ref.pdf]
Preview
Text
RAMA_13201_10011181722095__0021117801_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (773kB) | Preview
[thumbnail of RAMA_13201_10011181722095_0021117801_02.pdf] Text
RAMA_13201_10011181722095_0021117801_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (388kB) | Request a copy
[thumbnail of RAMA_13201_10011181722095_0021117801_03.pdf] Text
RAMA_13201_10011181722095_0021117801_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (277kB) | Request a copy
[thumbnail of RAMA_13201_10011181722095_0021117801_04.pdf] Text
RAMA_13201_10011181722095_0021117801_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (510kB) | Request a copy
[thumbnail of RAMA_13201_10011181722095_0021117801_05.pdf] Text
RAMA_13201_10011181722095_0021117801_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (167kB) | Request a copy
[thumbnail of RAMA_13201_10011181722095_0021117801_06_ref.pdf] Text
RAMA_13201_10011181722095_0021117801_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (137kB) | Request a copy
[thumbnail of RAMA_13201_10011181722095_0021117801_07_lamp.pdf] Text
RAMA_13201_10011181722095_0021117801_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy

Abstract

The use of the machine has noise with a high-power sound. The negative impact is noise that is harmful to employees. Indonesian data explains that the prevalence of deafness is rather high, namely 4.6%. Workers are not aware of the incidence of complaints suffered so that the sensitivity of the ear can temporarily change to dominant sensitivity. The purpose of this study was to analyze the factors associated with hearing complaints of non-auditory effects on machine area workers at PT PLN (Persero) Unit Layanan Pusat Listrik Indralaya. This research method is quantitative with a cross sectional study design. The population in this study were 90 workers. The sample in total is 35 people selected by simple random sampling method and data analysis using chi square or fisher exact test. The results showed that the highest noise intensity was obtained at the source of the GT 12 engine at 87.5 dB (A), the hearing complaints of workers in the PT PLN ULPL Indralaya engine area (25.7%). Frequency distribution of worker age < 40 years (77.1%), working period < 5 years (51.4%), working duration < 8 hours (65.7%), and noise intensity < 85 dB (65.7%) . Variables related to hearing complaints were years of service (p-value = 0.007), length of work (p-value = 0.003) and noise intensity (p-value = 0.038). It can be concluded that there is a relationship between working period, length of work and noise intensity with hearing complaints in workers, substitution control in the company does not replace noise sources with machines that have lower noise intensity. It is hoped that this research can be the basis for related parties to install silencers at noise sources if possible by installing insulation on generator engines at PLN which is the source of noise and the company's efforts to carry out overall audiometric inspection activities for workers.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: kebisingan, keluhan pendengaran, pekerja
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD878-894 Special types of environment Including soil pollution, air pollution, noise pollution
Divisions: 10-Faculty of Public Health > 13201-Public Health (S1)
Depositing User: Chelsea Deka There
Date Deposited: 02 Feb 2022 01:16
Last Modified: 02 Feb 2022 01:16
URI: http://repository.unsri.ac.id/id/eprint/63655

Actions (login required)

View Item View Item