VALIDASI METODE SPEKTROFOTOMETRI UV/VIS UNTUK ANALISIS FORMALIN PADA SAMPEL IKAN

LUMBANGAOL, KENNEDY M. and Suheryanto, Suheryanto and Purwaningrum, Widia (2013) VALIDASI METODE SPEKTROFOTOMETRI UV/VIS UNTUK ANALISIS FORMALIN PADA SAMPEL IKAN. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_47201_08061003034.pdf] Text
RAMA_47201_08061003034.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (38MB) | Request a copy
[thumbnail of RAMA_47201_08061003034_0025066004_0003047305_01_front_ref.pdf]
Preview
Text
RAMA_47201_08061003034_0025066004_0003047305_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (10MB) | Preview
[thumbnail of RAMA_47201_08061003034_0025066004_0003047305_02.pdf] Text
RAMA_47201_08061003034_0025066004_0003047305_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (19MB) | Request a copy
[thumbnail of RAMA_47201_08061003034_0025066004_0003047305_03.pdf] Text
RAMA_47201_08061003034_0025066004_0003047305_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_47201_08061003034_0025066004_0003047305_04.pdf] Text
RAMA_47201_08061003034_0025066004_0003047305_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_47201_08061003034_0025066004_0003047305_05.pdf] Text
RAMA_47201_08061003034_0025066004_0003047305_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (474kB) | Request a copy
[thumbnail of RAMA_47201_08061003034_0025066004_0003047305_06_ref.pdf] Text
RAMA_47201_08061003034_0025066004_0003047305_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_47201_08061003034_0025066004_0003047305_07_lamp.pdf] Text
RAMA_47201_08061003034_0025066004_0003047305_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy

Abstract

The research about validation of visible spectrophotometry method to analyze formalin in fish had been done. The aim of this research was to determine several validation parameters such as precision, linearity, accuracy, limit of detection (LOD) and limit of quantification (LOQ). Formalin was added Nash reagent then detected using spectrophotometer at wave length 412 nm.The results of the research showed that validation parameters values for accuracy was 80.966%; Standard deviation value for formalin was 1.228%; linearity value for formalin was 0.999 ; LOD was 0.0976 pg/mL and LOQ was 0.32533 pg/mL, respectively. Due to the result of the research, visible spectrophotometry method to analyze formalin in fish was valid.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Validation, spectrophotometry, LOQ, LOD
Subjects: Q Science > QD Chemistry > QD71-142 Analytical chemistry
Divisions: 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1)
Depositing User: Mrs Furika Furika
Date Deposited: 23 Feb 2022 02:16
Last Modified: 23 Feb 2022 02:16
URI: http://repository.unsri.ac.id/id/eprint/65400

Actions (login required)

View Item View Item