ANALISIS KUALITAS BAKTERIOLOGI DAN HIGIENE SANITASI AIR MINUM PADA DEPOT AIR MINUM ISI ULANG DI KECAMATAN KALIDONI DAN SUMBANGANNYA PADA PEMBELAJARAN BIOLOGI DI SMA

KARIMA, MUTIARA FIRSTY and Nazip, Khoiron and Ermayanti, Ermayanti (2022) ANALISIS KUALITAS BAKTERIOLOGI DAN HIGIENE SANITASI AIR MINUM PADA DEPOT AIR MINUM ISI ULANG DI KECAMATAN KALIDONI DAN SUMBANGANNYA PADA PEMBELAJARAN BIOLOGI DI SMA. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_84205_06091381722068.pdf] Text
RAMA_84205_06091381722068.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_84205_06091381722068_TURNITIN.pdf] Text
RAMA_84205_06091381722068_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (5MB) | Request a copy
[thumbnail of RAMA_84205_06091381722068_0023016410_0003087601_01_front_ref.pdf]
Preview
Text
RAMA_84205_06091381722068_0023016410_0003087601_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Preview
[thumbnail of RAMA_84205_06091381722068_0023016410_0003087601_02.pdf] Text
RAMA_84205_06091381722068_0023016410_0003087601_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (385kB) | Request a copy
[thumbnail of RAMA_84205_06091381722068_0023016410_0003087601_03.pdf] Text
RAMA_84205_06091381722068_0023016410_0003087601_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (375kB) | Request a copy
[thumbnail of RAMA_84205_06091381722068_0023016410_0003087601_04.pdf] Text
RAMA_84205_06091381722068_0023016410_0003087601_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (533kB) | Request a copy
[thumbnail of RAMA_84205_06091381722068_0023016410_0003087601_05.pdf] Text
RAMA_84205_06091381722068_0023016410_0003087601_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (221kB) | Request a copy
[thumbnail of RAMA_84205_06091381722068_0023016410_0003087601_06_ref.pdf] Text
RAMA_84205_06091381722068_0023016410_0003087601_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (447kB) | Request a copy
[thumbnail of RAMA_84205_06091381722068_0023016410_0003087601_07_lamp.pdf] Text
RAMA_84205_06091381722068_0023016410_0003087601_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy

Abstract

Research on the quality of drinking water produced at the refill drinking water depot in Kalidoni district has been carried out with the aim of knowing the microbiological quality and sanitation hygiene of refilled drinking water. The research was carried out using a descriptive method with a cross sectional approach with a total sampling technique, namely sampling and observation and interview data were carried out at the same time. Data collection in this study includes two aspects, namely the microbiological quality of drinking water and the quality of sanitation hygiene. Data collection on microbiological quality aspects uses laboratory examinations using the MPN test method which refers to the 2012 WHO water quality monitoring program using microbiological parameters in the form of the total value of Coliform and E.coli bacteria while the sanitation hygiene quality aspect takes the form of surveys using hygiene observation sheets. The results of the study for the microbiological quality of drinking water showed that the total coliform bacteria from 8 depots with MPN index values per 100 ml respectively were 43/100 ml, >1100/100 ml, >1100/100 ml, >1100/100 ml, >1100 /100 ml, 539.6/100 ml, 427.6/100 ml, >1100/100 ml. the complete test is positive for fecal coliform bacteria. Data from the research on the quality of sanitation hygiene showed that only 68.75% of the depots met the sanitation hygiene requirements, namely 6 depots, out of 8 refill drinking water depots. The results of this study will be donated in the form of a non-experimental student worksheet (LKPD) in Basic Competence (KD) 3.11 to analyze data on environmental changes, their causes and impacts on health in Biology subjects in SMA class X even semesters.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: DAMIU, Kualitas Air Minum, Coliform, Higiene Sanitas
Subjects: Q Science > QR Microbiology
Q Science > QR Microbiology > QR1-502 Microbiology
Q Science > QR Microbiology > QR75-99.5 Bacteria
Divisions: 06-Faculty of Education and Educational Science > 84205-Biology Education (S1)
Depositing User: Mutiara Firsty Karima
Date Deposited: 26 Jul 2022 06:45
Last Modified: 26 Jul 2022 06:45
URI: http://repository.unsri.ac.id/id/eprint/73201

Actions (login required)

View Item View Item