ZULKARNAIN, ARY and Kuncoro, Endo Argo and Hasbi, Hasbi (2018) DESAIN SISTEM PENDINGIN AGAR – AGAR MENGGUNAKAN PELTIER SEBAGAI SUMBER PENDINGIN. Undergraduate thesis, Sriwijaya University.
Preview |
Text
RAMA_41201_05021181320006_0005076105_0004116001_01_Front_Ref..pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (1MB) | Preview |
Text
RAMA_41201_05021181320006_0005076105_0004116001_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (82kB) | Request a copy |
|
Text
RAMA_41201_05021181320006_0005076105_0004116001_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (103kB) | Request a copy |
|
Text
RAMA_41201_05021181320006_0005076105_0004116001_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (647kB) | Request a copy |
|
Text
RAMA_41201_05021181320006_0005076105_0004116001_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (84kB) | Request a copy |
|
Text
RAMA_41201_05021181320006_0005076105_0004116001_06_Ref..pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (98kB) | Request a copy |
|
Text
RAMA_41201_05021181320006_0005076105_0004116001_07_Lamp..pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (396kB) | Request a copy |
Abstract
The design of jelly cooling system using a peltier was aimed to accelerate the cooling process of jelly compared to conventional cooling at normal time. This research was conducted from Juni 2017 to Desember 2017 at Laboratorium Energi and Electrification of Agricultural Technology Sriwijaya University. This research using peltier TEC-12706 as component for cooling system. The method use in this research was descriptive method with three stages of research that are to design the tool . operate the tool and the testing the tool. The observed parameters were the power required during tool operated. The changing temperatureand the timed needed fot that process. The result show that the power required during the tool operating is 129.1 W and the power need of pump is 0.107 kWh in every experiment. The time generated by the peltier cooling system is a 50 minute whereas by the conventional system is 90 minutes.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Jelly, Cooling, Peltier. |
Subjects: | S Agriculture > S Agriculture (General) > S1-(972) Agriculture (General) S Agriculture > S Agriculture (General) > S539.5-542.3 Research. Experimentation |