SPESIASI ION LOGAM Cr(III) DAN Cr(VI) MENGGUNAKAN METODE POTENSIOMETRI DI PERAIRAN SEKITAR TPA SUKAWINATAN KOTA PALEMBANG

GIANSYAH, ACHMAD FACHMI and Suheryanto, Suheryanto and Muharni, Muharni (2022) SPESIASI ION LOGAM Cr(III) DAN Cr(VI) MENGGUNAKAN METODE POTENSIOMETRI DI PERAIRAN SEKITAR TPA SUKAWINATAN KOTA PALEMBANG. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_47201_08031381520064.pdf] Text
RAMA_47201_08031381520064.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_47201_08031381520064_TURNITIN.pdf] Text
RAMA_47201_08031381520064_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_47201_08031381520064_0025066004_004036903_01_front_ref.pdf]
Preview
Text
RAMA_47201_08031381520064_0025066004_004036903_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (462kB) | Preview
[thumbnail of RAMA_47201_08031381520064_0025066004_004036903_02.pdf] Text
RAMA_47201_08031381520064_0025066004_004036903_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (128kB) | Request a copy
[thumbnail of RAMA_47201_08031381520064_0025066004_004036903_03.pdf] Text
RAMA_47201_08031381520064_0025066004_004036903_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (302kB) | Request a copy
[thumbnail of RAMA_47201_08031381520064_0025066004_004036903_04.pdf] Text
RAMA_47201_08031381520064_0025066004_004036903_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (351kB) | Request a copy
[thumbnail of RAMA_47201_08031381520064_0025066004_004036903_05.pdf] Text
RAMA_47201_08031381520064_0025066004_004036903_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (7kB) | Request a copy
[thumbnail of RAMA_47201_08031381520064_0025066004_004036903_06_ref.pdf] Text
RAMA_47201_08031381520064_0025066004_004036903_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (82kB) | Request a copy
[thumbnail of RAMA_47201_08031381520064_0025066004_004036903_07_lamp.pdf] Text
RAMA_47201_08031381520064_0025066004_004036903_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (414kB) | Request a copy

Abstract

Speciation studies of Cr3+ and Cr6+ ions have been carried out using the potentiometric method of the concentration cell system. The purpose of the study was to determine the levels of metal ion species Cr(III) and Cr(VI) and to study the distribution of metal ions Cr(III) and Cr(VI) in the Sukawinatan TPA waters in the core zone, buffer zone, and cultivation zone of the Sukawinatan TPA Palembang. The concentration cell potentiometric method consisted of a chromium metal anode and a cathode immersed in an electrolyte solution of chromium ions with different concentrations of the KNO3 salt bridge. The cell potential is measured with a voltmeter. This method is valid for Cr3+ ions with LoD and LoQ of 0.2910 mg/mL and 0.3036 mg/L, while LoD and LoQ of Cr6+ ions are 0.3142 mg/L and 0.6127 mg/L. The precision of the method is based on %RSD for Cr3+ ions 0.1473% and Cr6+ ions 1.2635%, with accuracy reaching 88.521 % for Cr3+ ions and 115.889% for Cr6+ ions. The levels of Cr3+ ions in the leachate at the leachate inlet, pond 1, pond 2, and zone 1 show between 0,517 mg/L to 1,632 mg/L, while for community environmental zones such as rivers, canals, and community standards, it is between 0,296 mg/mL to 0.313 mg/mL. +. The levels of Cr6+ ions in the leachate at the leachate inlet, pond 1, pond 2, and zone 1 show between 0.518 mg/L to 9.787 mg/L, while for community environmental zones such as rivers, canals, and community standards, it is between 0.298 mg/mL to 0.319 mg/mL. The distribution of the curves showed that the highest concentration in the tested area was the value of Cr6+ (9,787 mg/mL) higher than that of Cr3+ (1,632 mg/mL).

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: potentiometry, cell concentration, speciation, chromium
Subjects: Q Science > QD Chemistry > QD71-142 Analytical chemistry
Divisions: 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1)
Depositing User: Achmad Fachmi Giansyah
Date Deposited: 04 Aug 2022 07:03
Last Modified: 04 Aug 2022 07:03
URI: http://repository.unsri.ac.id/id/eprint/75871

Actions (login required)

View Item View Item