LEO, MATHIUS and Saloma, Saloma and Idris, Yakni (2016) STUDI PERILAKU STRUKTUR RANGKA BAJA K-BRACED DAN X-BRACED CBF (CONCENTRICALLY BRACED FRAMES) DENGAN ANALISIS PUSHOVER. Undergraduate thesis, Sriwijaya University.
Text
RAMA_03121401033_0031107601_0011125802.pdf - Accepted Version Restricted to Repository staff only Download (5MB) | Request a copy |
|
Preview |
Text
RAMA_03121401033_0031107601_0011125802_01_front_ref.pdf - Accepted Version Download (1MB) | Preview |
Text
RAMA_03121401033_0031107601_0011125802_02.pdf - Accepted Version Restricted to Repository staff only Download (1MB) | Request a copy |
|
Text
RAMA_03121401033_0031107601_0011125802_03.pdf - Accepted Version Restricted to Repository staff only Download (136kB) | Request a copy |
|
Text
RAMA_03121401033_0031107601_0011125802_04.pdf - Accepted Version Restricted to Repository staff only Download (208kB) | Request a copy |
|
Text
RAMA_03121401033_0031107601_0011125802_05.pdf - Accepted Version Restricted to Repository staff only Download (383kB) | Request a copy |
|
Text
RAMA_03121401033_0031107601_0011125802_06.pdf - Accepted Version Restricted to Repository staff only Download (52kB) | Request a copy |
|
Text
RAMA_03121401033_0031107601_0011125802_06_ref.pdf - Accepted Version Restricted to Repository staff only Download (87kB) | Request a copy |
|
Text
RAMA_03121401033_0031107601_0011125802_07_lamp.pdf - Accepted Version Restricted to Repository staff only Download (2MB) | Request a copy |
Abstract
Earthquake retaining structures required to reduced the negative effect of earthquake. This Building with steel structure use steel Concentrically Braced Frame (CBF). This research used 5 models of steel buildings with the same size 18 m x 18 m and the height 40 m. This buildings serves as an office building and was built on soft soil condition. Steel building used 2 types of bracing CBF, Xbraced and K-braced. The result of pushover analysis was perfomance level, pushover curve, plastic hinge distribution. The result of research found out that X braced is the most effective to increase rigidity and strength building. Model 4 can reduce displacement 40,045% in x direction and 56,079% in y direction. Model 4 can reduce drift ratio 50,685% in x direction and 62,423% in y direction, model 4 aslo has maximum drift ratio in 7th floor. Model 4 also has the biggest shear force at performance point with that is 1193,943 ton in x direction and 1134,332 ton in y direction. The result of analysis pushover is every model has performance level in immediate occupancy.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | bracing, drift ratio, pushover, plastic hinge, performance level |
Subjects: | T Technology > TA Engineering (General). Civil engineering (General) > TA1-2040 Engineering (General). Civil engineering (General) > TA145 General works. Civil engineering, etc. 1850- |
Divisions: | 03-Faculty of Engineering > 22201-Civil Engineering (S1) |
Depositing User: | Prof Amrifan Saladin Mohruni |
Date Deposited: | 16 Sep 2019 12:11 |
Last Modified: | 16 Sep 2019 12:11 |
URI: | http://repository.unsri.ac.id/id/eprint/7798 |
Actions (login required)
View Item |