similiarity_Deep learning-based electrocardiogram rhythm and beat features for heart abnormality classification

firdaus, firdaus (2022) similiarity_Deep learning-based electrocardiogram rhythm and beat features for heart abnormality classification. Turnitin Universitas Sriwijaya.

[thumbnail of 10.pdf] Text
10.pdf - Other

Download (6MB)

Abstract

Background. Electrocardiogram (ECG) signal classification plays a critical role in the automatic diagnosis of heart abnormalities. While most ECG signal patterns cannot be recognized by a human interpreter, they can be detected with precision using artificial intelligence approaches, making theECGa powerful non-invasive biomarker. However, performing rapid and accurate ECG signal classification is difficult due to the low amplitude, complexity, and non-linearity. The widely-available deep learning (DL) method we propose has presented an opportunity to substantially improve the accuracy of automatedECGclassification analysis using rhythm or beat features. Unfortunately, a comprehensive and general evaluation of the specific DL architecture for ECG analysis across a wide variety of rhythm and beat features has not been previously reported. Some previous studies have been concerned with detecting ECG class abnormalities only through rhythm or beat features separately. Methods. This study proposes a single architecture based on the DL method with onedimensional convolutional neural network (1D-CNN) architecture, to automatically classify 24 patterns of ECG signals through both rhythm and beat. To validate the proposed model, five databases which consisted of nine-class of ECG-base rhythm and 15-class of ECG-based beat were used in this study. The proposed DL network was applied and studied with varying datasets with different frequency samplings in intra and inter-patient scheme. Results. Using a 10-fold cross-validation scheme, the performance results had an accuracy of 99.98%, a sensitivity of 99.90%, a specificity of 99.89%, a precision of 99.90%, and an F1-score of 99.99% for ECG rhythm classification. Additionally, for ECG beat classification, the model obtained an accuracy of 99.87%, a sensitivity of 96.97%, a specificity of 99.89%, a precision of 92.23%, and an F1-score of 94.39%. In conclusion, this study provides clinicians with an advanced methodology for detecting and discriminating heart abnormalities between different ECG rhythm and beat assessments by using one outstanding proposed DL architecture. © 2022 Darmawahyuni et al

Item Type: Other
Subjects: #3 Repository of Lecturer Academic Credit Systems (TPAK) > Results of Ithenticate Plagiarism and Similarity Checker
Divisions: 09-Faculty of Computer Science > 56201-Computer Systems (S1)
Depositing User: Mr Firdaus Firdaus
Date Deposited: 18 Mar 2023 00:02
Last Modified: 18 Mar 2023 00:02
URI: http://repository.unsri.ac.id/id/eprint/90906

Actions (login required)

View Item View Item