ANALISA EFEK TRIMMING IMPELLER TERHADAP PERFOMANSI POMPA SENTRIFUGAL JENIS CP 200

SITORUS, SAMUEL CHRISTIAN and Marwani, Marwani (2018) ANALISA EFEK TRIMMING IMPELLER TERHADAP PERFOMANSI POMPA SENTRIFUGAL JENIS CP 200. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_21201_03051281419073_0022036505_01_front_ref.pdf]
Preview
Text
RAMA_21201_03051281419073_0022036505_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Preview
[thumbnail of RAMA_21201_03051281419073_0022036505_02.pdf] Text
RAMA_21201_03051281419073_0022036505_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (310kB) | Request a copy
[thumbnail of RAMA_21201_03051281419073_0022036505_03.pdf] Text
RAMA_21201_03051281419073_0022036505_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (469kB) | Request a copy
[thumbnail of RAMA_21201_03051281419073_0022036505_04.pdf] Text
RAMA_21201_03051281419073_0022036505_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (620kB) | Request a copy
[thumbnail of RAMA_21201_03051281419073_0022036505_05.pdf] Text
RAMA_21201_03051281419073_0022036505_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (137kB) | Request a copy
[thumbnail of RAMA_21201_03051281419073_0022036505_07_lamp.pdf] Text
RAMA_21201_03051281419073_0022036505_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (835kB) | Request a copy
[thumbnail of RAMA_21201_03051281419073_0022036505_06_ref.pdf] Text
RAMA_21201_03051281419073_0022036505_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (135kB) | Request a copy

Abstract

This research aims to get a graph of the relationship between capacity (Q) and head (H), capacity (Q) and water resources (Ph), and capacity (Q) and Efficiency (%) for different diameter of impeller prior to and after doing the cutting (trimming). This is only done research on centrifugal pump type CP 200 maximum capacity (Q) 30 litres/minute, head 20 metres. The research method used was experimental methods, by making the test device then performs data retrieval is needed and do the calculation and get the results in the form of tables and charts as well as the conclusion. Once he did, the study of literature in the research of this thesis is done testing with use of centrifugal pump with suction pipe size requirements used by 1 inch or 2.54 cm. in this final task research do the impeller trimming (pruning of the impeller) twice (12, 95Cm; 12, 90Cm). Changes of relative small pump characteristics due to the trimming done sangan small (0.5 mm), can be seen from the graph obtained showed few changes caused by trimming. We can conclude that the impeller trimming is done on this testing can lower capacity (according to the theory) on each diameter and impeller diameter 12.9 has the capacity of most small value of 1.51 l/s at a speed round N1 debit 1. There is a significant difference between the measurement and analysis of the calculation using the law of Kesebangunan, where the results of analysis of the law of Kesebangunan have a greater value, look at the graph of H vs. Q, Ph vs. Efficiency vs. Q, Q on each diameter impeller, this is because trimming is done not to use machining processes (the use of a lathe), which causes the shape of the impeller are not precision. The result of the measurement head impeller the impeller is larger than the ditrimming who have not ditrimming like in the N1 (2000rpm) for diameter 12, 95cm with a value of 17, 73m, and to the diameter of a passer-by with a value of 15, 75 m, this disebakan because of pressure gauge used less thorough and caused also by the installation of the valve too far away from the pump. The results of this research are expected to enrich the study of centrifugal pumps and usability of cutting impeller (impeller trimming), and can contribute towards knowledge or influence of cutting impeller (impeller trimming) centrifugal pumps.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: centrifugal pumps, impeller, trimming, perfomance
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ1-1570 Mechanical engineering and machinery
Divisions: 03-Faculty of Engineering > 21201-Mechanical Engineering (S1)
Depositing User: Users 2701 not found.
Date Deposited: 15 Nov 2019 04:04
Last Modified: 15 Nov 2019 04:04
URI: http://repository.unsri.ac.id/id/eprint/16043

Actions (login required)

View Item View Item