ANALISIS ENERGI DAN EKSERGI PADA SISTEM KOGENERASI TURBIN GAS PT.PUSRI PALEMBANG

ALIM, NAQLI and Santoso, Dyos and Riady, M. Ihsan (2020) ANALISIS ENERGI DAN EKSERGI PADA SISTEM KOGENERASI TURBIN GAS PT.PUSRI PALEMBANG. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_21201_03051281621045.pdf] Text
RAMA_21201_03051281621045.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (4MB) | Request a copy
[thumbnail of RAMA_21201_03051281621045_TURNITIN.pdf] Text
RAMA_21201_03051281621045_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (4MB) | Request a copy
[thumbnail of RAMA_21201_03051281621045_0023126009_0013108702_01_front_ref.pdf]
Preview
Text
RAMA_21201_03051281621045_0023126009_0013108702_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Preview
[thumbnail of RAMA_21201_03051281621045_0023126009_0013108702_02.pdf] Text
RAMA_21201_03051281621045_0023126009_0013108702_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (990kB) | Request a copy
[thumbnail of RAMA_21201_03051281621045_0023126009_0013108702_03.pdf] Text
RAMA_21201_03051281621045_0023126009_0013108702_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (562kB) | Request a copy
[thumbnail of RAMA_21201_03051281621045_0023126009_0013108702_04.pdf] Text
RAMA_21201_03051281621045_0023126009_0013108702_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (454kB) | Request a copy
[thumbnail of RAMA_21201_03051281621045_0023126009_0013108702_05.pdf] Text
RAMA_21201_03051281621045_0023126009_0013108702_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (773kB) | Request a copy
[thumbnail of RAMA_21201_03051281621045_0023126009_0013108702_06.pdf] Text
RAMA_21201_03051281621045_0023126009_0013108702_06.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (449kB) | Request a copy
[thumbnail of RAMA_21201_03051281621045_0023126009_0013108702_07_ref.pdf] Text
RAMA_21201_03051281621045_0023126009_0013108702_07_ref.pdf - Bibliography
Restricted to Repository staff only

Download (449kB) | Request a copy
[thumbnail of RAMA_21201_03051281621045_0023126009_0013108702_08_lamp.pdf] Text
RAMA_21201_03051281621045_0023126009_0013108702_08_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (963kB) | Request a copy

Abstract

This study deals with the energetic and exergetic performance evaluation was conducted on a cogeneration system (combined heat and power) of the fertilizer plant of PT. Pusri Palembang. The systems consist of a gas turbine system (compressor, combustion chamber and gas turbine) as an electric power generating and a supplemented fired waste heat boiler (economizer, evaporator and super heater) as a steam generator for process requirement. Quantitative energy and exergy balance for each component and the whole system was considered, while energy losses and exergy destruction within the system were determined. The performance characteristics of this cogeneration system were evaluated using energy and exergy analyses methods. The results show that the energetic and exergetic efficiencies of the gas turbine cogeneration system are 74,45 % with 63.190,17 kW (as power: 7.651,00 kW and superheated steam@677 K: 55.539,17 kW and 11,16 % with 38.172,97 kW (as power: 7.651,00 kW and superheated steam@677 K: 30.521,96 kW, respectively. The highest exergy destruction occurs in refiring process as 33.123,13 kW, i.e. 37,93% of the total exergy destruction of the system or 33,70% of the total exergy of the fuel. While the lowest exergy destruction occurs in economizer as 1.533,73 kW, i.e. 1,75% of the total exergy destruction of the system or 1,56% of the total exergy of the fuel.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Analisis Energi, Analisis Eksergi, Kogenerasi, Kombinasi Kalor dan Daya, Turbin Gas dan Supplemented Fired WHB
Subjects: T Technology > TJ Mechanical engineering and machinery > TJ163.13-163.25 Power resources
Divisions: 03-Faculty of Engineering > 21201-Mechanical Engineering (S1)
Depositing User: Users 5806 not found.
Date Deposited: 08 Jun 2020 06:51
Last Modified: 08 Jun 2020 06:51
URI: http://repository.unsri.ac.id/id/eprint/29768

Actions (login required)

View Item View Item