KARAKTERISTIK TEGANGAN PELUAHAN AWAL DAN TEGANGAN TEMBUS PADA ISOLASI KERTAS KRAFT DENGAN DIBERI UAP AIR DAN VCO

JIWANDONO, NOVAL and Kurnia, Rizda Fitri (2021) KARAKTERISTIK TEGANGAN PELUAHAN AWAL DAN TEGANGAN TEMBUS PADA ISOLASI KERTAS KRAFT DENGAN DIBERI UAP AIR DAN VCO. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_20201_03041381621092.pdf] Text
RAMA_20201_03041381621092.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (5MB) | Request a copy
[thumbnail of RAMA_20201_03041381621092_TURNITIN.pdf] Text
RAMA_20201_03041381621092_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_20201_03041381621092_0031058703_01_front_ref.pdf]
Preview
Text
RAMA_20201_03041381621092_0031058703_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Preview
[thumbnail of RAMA_20201_03041381621092_0031058703_02.pdf] Text
RAMA_20201_03041381621092_0031058703_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (424kB) | Request a copy
[thumbnail of RAMA_20201_03041381621092_0031058703_03.pdf] Text
RAMA_20201_03041381621092_0031058703_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (535kB) | Request a copy
[thumbnail of RAMA_20201_03041381621092_0031058703_04.pdf] Text
RAMA_20201_03041381621092_0031058703_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (476kB) | Request a copy
[thumbnail of RAMA_20201_03041381621092_0031058703_05.pdf] Text
RAMA_20201_03041381621092_0031058703_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (149kB) | Request a copy
[thumbnail of RAMA_20201_03041381621092_0031058703_06_ref.pdf] Text
RAMA_20201_03041381621092_0031058703_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (275kB) | Request a copy
[thumbnail of RAMA_20201_03041381621092_0031058703_07_lamp.pdf] Text
RAMA_20201_03041381621092_0031058703_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy

Abstract

This research about the characteristic of Partial Discharge (PD) and Breakdown Voltage of kraft paper insulation. This research used kraft paper with a thickness 40 µm. The sample was made with a size of 5 cm x 5 cm. The sample were treated under two different conditions uisng water condensation and Virgin Coconut Oil (VCO). After condensing, the kraft paper was then dried with a variation of 12 hours, 24 hours, 36 hours, and 48 hours. Measurement of the Partial Discharge and Breakdown Voltage was carried out with needle-plane electrode system using High Voltage Alternating Current (HVAC) between the sample surface and the needle electrode with the gap of 0.1 mm. From the measurement results on sample which were given water condensate, it can be seen that the discharge and Breakdown Voltage tend to increase. The highest Partial Discharge of kraft paper samples given water after recovery was in the recovery time of 24 hours, which was 1.864 kV, while the highest value of Breakdown Voltage was the recovery time of 48 hours, which was 2.773 kV. For the measurement of kraft paper samples given VCO, it can be seen that the Partial Discharge and the Breakdown Voltage have increased. The highest Partial Discharge of kraft paper samples given VCO was the recovery time of 12 hours, which was 1.8778 kV, while the Breakdown Voltage value was 36 hours, which was 3.0398 kV. The increase in Partial Discharge and Breakdown Voltage in kraft paper were given water condensate and kraft paper were given VCO affected by the capacitance in kraft paper, temperature, and humidity.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Kraft Paper, Partial Discharge Inception Voltage, Breakdown Voltage, Water Condensate, Virgin Coconut Oil
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK452-454.4 Electric apparatus and materials. Electric circuits. Electric networks
Divisions: 03-Faculty of Engineering > 20201-Electrical Engineering (S1)
Depositing User: Users 10539 not found.
Date Deposited: 16 Mar 2021 06:40
Last Modified: 16 Mar 2021 06:40
URI: http://repository.unsri.ac.id/id/eprint/43790

Actions (login required)

View Item View Item