GINTING, FERNANDO BASTANTA and Jambak, Muhammad Irfan (2022) EVALUASI DAN PERANCANGAN SISTEM PROTEKSI PETIR EKSTERNAL PADA BANGUNAN UPT TIK STUDENT CENTER UNIVERSITAS SRIWIJAYA BERDASARKAN IEC 62305. Undergraduate thesis, Sriwijaya University.
Text
RAMA_20201_03041181823015.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (7MB) | Request a copy |
|
Text
RAMA_20201_03041181823015_TURNITIN.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (8MB) | Request a copy |
|
Preview |
Text
RAMA_20201_03041181823015_0001107106_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (1MB) | Preview |
Text
RAMA_20201_03041181823015_0001107106_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
|
Text
RAMA_20201_03041181823015_0001107106_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (808kB) | Request a copy |
|
Text
RAMA_20201_03041181823015_0001107106_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
|
Text
RAMA_20201_03041181823015_0001107106_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (145kB) | Request a copy |
|
Text
RAMA_20201_03041181823015_0001107106_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (206kB) | Request a copy |
|
Text
RAMA_20201_03041181823015_0001107106_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (3MB) | Request a copy |
Abstract
The current buildings tend to be more multi-storey and wide, this is because the existing land is getting narrower. The taller and wider the multi-storey building, the more things that must be considered in the building. One of the disturbances in tall and wide buildings is a lightning strike. Therefore it is necessary to consider protecting a building. This study aims to evaluate the lightning protection system installed using the electrogeometric method and to design a lightning protection system using the Rolling Sphere Method at the UPT TIK Student Center Sriwijaya University building. The results with the electrogeometric method on the UPT TIK building with 1 air termination installed, the striking distance is 125.59 meters with a protection angle of 58.87⁰ and a protection radius of 64.78 meters. From the results of this evaluation, it can be seen that there are still parts of the building that have not been optimally protected, so the design is carried out using the Rolling Sphere Method. In this design, it is known that 13 air terminations need to be added with a height of 1 meter and a total length of 587,64 meters and 4 down conductors with a total length of 48 meters.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Metode Elektrogeometri, Metode Bola Bergulir, IEC 62305. |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK301-399 Electric meters T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK4125-4399 Electric lighting |
Divisions: | 03-Faculty of Engineering > 20201-Electrical Engineering (S1) |
Depositing User: | Fernando Bastanta Ginting |
Date Deposited: | 13 Sep 2022 07:26 |
Last Modified: | 14 Sep 2022 01:41 |
URI: | http://repository.unsri.ac.id/id/eprint/78725 |
Actions (login required)
View Item |