ANALISIS PENGARUH PANJANG DAN JUMLAH LILITAN KAWAT KUMPARAN PADA MESIN STERILISASI ALAT MEDIS PORTABLE

ARITONANG, ERIKSON JUNAIDI and Rahmawati, Rahmawati (2023) ANALISIS PENGARUH PANJANG DAN JUMLAH LILITAN KAWAT KUMPARAN PADA MESIN STERILISASI ALAT MEDIS PORTABLE. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_20201_03041181924021.pdf] Text
RAMA_20201_03041181924021.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_20201_03041181924021_TURNITIN.pdf] Text
RAMA_20201_03041181924021_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_20201_03041181924021_0026117701_01_front_ref.pdf] Text
RAMA_20201_03041181924021_0026117701_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_20201_03041181924021_0026117701_02.pdf] Text
RAMA_20201_03041181924021_0026117701_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (432kB) | Request a copy
[thumbnail of RAMA_20201_03041181924021_0026117701_03.pdf] Text
RAMA_20201_03041181924021_0026117701_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (396kB) | Request a copy
[thumbnail of RAMA_20201_03041181924021_0026117701_04.pdf] Text
RAMA_20201_03041181924021_0026117701_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (263kB) | Request a copy
[thumbnail of RAMA_20201_03041181924021_0026117701_05.pdf] Text
RAMA_20201_03041181924021_0026117701_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (32kB) | Request a copy
[thumbnail of RAMA_20201_03041181924021_0026117701_06_ref.pdf] Text
RAMA_20201_03041181924021_0026117701_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (95kB) | Request a copy
[thumbnail of RAMA_20201_03041181924021_0026117701_07_lamp.pdf] Text
RAMA_20201_03041181924021_0026117701_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (247kB) | Request a copy

Abstract

An induction heater or what can be called also an induction heater is a device or circuit that is capable of producing heat and heating objects with an induction system. The principle of heating due to the presence of eddy currents generated by the magnetic flux originating from the coil that is energized by alternating electric current. This induction heater has been widely used in all fields, one of which is in the health sector, namely in medical device sterilization machines. To make a heat induction device for a sterilizer requires several components, namely a power supply, an induction heating module, and a working coil wire, so that voltage, current, time to reach the sterilization temperature of 170 °C can be measured as well as the calculation of the power and heat energy required. generated. In this study, the length and number of coil wires used in the sterilizer were tested, namely a coil length of 7 meters with a total of 53 coils, a coil length of 9 meters with a total of 58 coils, and a length of 11 meters with a total of 63 coils. Where of the three lengths and the number of turns used at a length of 7 meters produces the largest voltage, current and power, namely 55 Volts, 4.04 Amperes and 111.1 Watts and at a length of 11 meters produces the highest voltage, current and power small, namely 50.6 Volts, 2.08 Amperes, 52.624 Watts. The fastest heating time was found on a coil wire length of 11 meters, namely 26.25 minutes and the longest on a wire length of 7 meters, which was 37.20 minutes. The results showed that the length and number of turns of the coil wire affect the value of the voltage, current, and power produced, this is because the length and number of turns determine the size of the induced emf and the resulting magnetic flux. The size of the generated magnetic flux depends on the area of the induction coil used. Keywords : induction heating, sterilization machines, number of turns, induction emf

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: pemanas induksi, mesin sterilissasi, jumlah lilitan, ggl induksi
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3001-3521 Distribution or transmission of electric power
Divisions: 03-Faculty of Engineering > 20201-Electrical Engineering (S1)
Depositing User: Erikson Junaidi Aritonang
Date Deposited: 08 Jun 2023 03:25
Last Modified: 08 Jun 2023 03:25
URI: http://repository.unsri.ac.id/id/eprint/107607