Multichannel Data Aquisition System for Monitoring Supercapacitor Module and Cells. Correspondence

Nirwan Syarif, - and Assaidah, - (2016) Multichannel Data Aquisition System for Monitoring Supercapacitor Module and Cells. Correspondence. UAD.

[thumbnail of Multichannel Data Aquisition System Correspondence] Text (Multichannel Data Aquisition System Correspondence)
Multichannel Data Aquisition Telkomnika Nirwan Syarif 2016 Corres.pdf

Download (1MB)

Abstract

The monitoring system is needed to observe changes in the voltage of supercapacitor module and cells so that their performance can be assessed. A multichannel data acquisition system was needed to implement because a module of supercapacitor consists of several individual cells. The system can be implemented in a computer program using data acquisition board and computer programming. The computer program acts as computer and user interface was created by using Labview symbolic programming software, while the data acquisition board was Labjack. The test showed that the monitoring system can receive eight channel of input signal (voltage) of the module and cells simultaneously. The voltage of the module which has a wider range, 0-20 volts, rather than the normal input, 0 to 2.44 volts, can be overcome by adding a voltage divider circuit.

Item Type: Other
Subjects: #3 Repository of Lecturer Academic Credit Systems (TPAK) > Corresponding Author
Divisions: 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1)
Depositing User: Dr Nirwan Syarif
Date Deposited: 20 Jun 2023 02:09
Last Modified: 20 Jun 2023 02:09
URI: http://repository.unsri.ac.id/id/eprint/108625

Actions (login required)

View Item View Item