ANAlISIS SISTEM PENGELOLAAN LIMBAH CAIR DI RUMAH SAKIT KUSTA DR. RIVAI ABDULLAH PALEMBANG TAHUN 2019

AFRIANI, AYU and Septiawati, Dwi (2019) ANAlISIS SISTEM PENGELOLAAN LIMBAH CAIR DI RUMAH SAKIT KUSTA DR. RIVAI ABDULLAH PALEMBANG TAHUN 2019. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_13201_10011181520249.pdf] Text
RAMA_13201_10011181520249.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (7MB) | Request a copy
[thumbnail of RAMA_13201_10011181520249_TURNITIN.pdf] Text
RAMA_13201_10011181520249_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (43MB) | Request a copy
[thumbnail of RAMA_13201_10011181520249_8886630017_01_front_ref.pdf] Text
RAMA_13201_10011181520249_8886630017_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (2MB)
[thumbnail of RAMA_13201_10011181520249_8886630017_02.pdf] Text
RAMA_13201_10011181520249_8886630017_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (352kB) | Request a copy
[thumbnail of RAMA_13201_10011181520249_8886630017_03.pdf] Text
RAMA_13201_10011181520249_8886630017_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (184kB) | Request a copy
[thumbnail of RAMA_13201_10011181520249_8886630017_04.pdf] Text
RAMA_13201_10011181520249_8886630017_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (129kB) | Request a copy
[thumbnail of RAMA_13201_10011181520249_8886630017_05.pdf] Text
RAMA_13201_10011181520249_8886630017_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (394kB) | Request a copy
[thumbnail of RAMA_13201_10011181520249_8886630017_06.pdf] Text
RAMA_13201_10011181520249_8886630017_06.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (283kB) | Request a copy
[thumbnail of RAMA_13201_10011181520249_8886630017_07.pdf] Text
RAMA_13201_10011181520249_8886630017_07.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (93kB) | Request a copy
[thumbnail of RAMA_13201_10011181520249_8886630017_08_ref.pdf] Text
RAMA_13201_10011181520249_8886630017_08_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (141kB) | Request a copy
[thumbnail of RAMA_13201_10011181520249_8886630017_09_lamp.pdf] Text
RAMA_13201_10011181520249_8886630017_09_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy

Abstract

Hospitals produce wastewater which can give the negative impact such as disruption to health, life and disruption of view and biotic’s life, so it should be treated before it is discharged into the environment. This study aims to analysis management of wastewater using systems approach which input (policies, human resources, facilities, and funding), processes (planning, organizing, operational techniques, and supervision), and the output of effluent quality. This research is qualitative descriptive approach. The research used the methode of in-depth interviews, observations, review of documents, and laboratory testing. Analysis was done by triangulation method, triangulation of sources, and triangulation of data. The sampling technique used purposive sampling technique which selected seven informants. The results showed that in the input aspect is known that benchmark policies are still not updated, there is no strict punishment for violator of SOP, and there are some of the fasilities and infrastucture that still have not met the requirements, in the process aspect is known that maintenance of infrastructure is not in accordance with the planning, the delay measurement of the quality of the wastewater, and the wastewater treatment process that is not yet perfect, and in the output aspect is known that the quality of the effluent still exceeded the limit of environmental quality standards is on parameters of pH and total Choliform. It can be concluded that each component in the aspects of input, process and output are flaws or problems. Suggestions from researcher that hospital should enhancement and improvement in each component of input, process and output by means of SWOT analysis, and then perform the appropriate repair priorities.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: IPAL, Kualitatif, Pengelolaan Limbah Cair.
Subjects: T Technology > TD Environmental technology. Sanitary engineering > TD429.5-480.7 Water purification. Water treatment and conditioning. Saline water conversion
Divisions: 10-Faculty of Public Health > 13201-Public Health (S1)
Depositing User: Administrator Library
Date Deposited: 29 Jul 2019 06:54
Last Modified: 07 Nov 2019 02:43
URI: http://repository.unsri.ac.id/id/eprint/1121

Actions (login required)

View Item View Item