WINATA, ERWIN DWI and Zaini, Syamsuri (2018) PERGESERAN SUDUT FASA AKIBAT PERBAIKAN FAKTOR KERJA STUDI KASUS DI PT.PDAM TIRTA BUKIT SULAP LUBUKLINGGAU. Undergraduate thesis, Sriwijaya University.
Preview |
Text
RAMA_20201_03041381320001_0004035804_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (2MB) | Preview |
Text
RAMA_20201_03041381320001_0004035804_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (575kB) | Request a copy |
|
Text
RAMA_20201_03041381320001_0004035804_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (586kB) | Request a copy |
|
Text
RAMA_20201_03041381320001_0004035804_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (704kB) | Request a copy |
|
Text
RAMA_20201_03041381320001_0004035804_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (225kB) | Request a copy |
|
Text
RAMA_20201_03041381320001_0004035804_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (117kB) | Request a copy |
|
Text
RAMA_20201_03041381320001_0004035804_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
Abstract
In the field of industry that many have electrical appliances that are inductive there are main problems that often faced is the bad power factor (cos rp). Poor Power factor (ros ,p) is Caused by the use of electrical appliances that are inductive.This results in increased use of reactive power used in inductive loads, as well as an increase in the amount of costs paid by firms due to the excessive use of reactive power. The working factor can be said to be bad when the magnitude <0.85. This is based on the provisions of PT. PLN (Persero) concerning the minimum limit of power factor on electrical, appliances that are inductive is 0.85 and if the industry has a power factor of <0.85 then it will be penalized in the case of excess reactive power consumption in accordance with applicable provisions. One way that can be done to overcome the problem of power factor (cos ,p) is to make improvement power factor (cos rp) by using capacitor bank. At PT.PDAM Tirta Bukit Sulap Lubuklinggau, the area of kayu ara has a power factor (cos <p) below the standard of 0. 79 and after repaired to 0.95 by using a bank capacitor of 20 KV AR. The addition of a bank capacitor leads to the release of the thermal capacity. This results in a shift in the phase angle occurring. so that initially is 0. 95 becomes 0. 909.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | Power Factor. Reactive Power, Bank Capacitor |
Subjects: | T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3001-3521 Distribution or transmission of electric power T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK452-454.4 Electric apparatus and materials. Electric circuits. Electric networks |
Divisions: | 03-Faculty of Engineering > 20201-Electrical Engineering (S1) |
Depositing User: | Mrs Dies Meirita Sari |