PERANCANGAN SISTEM MONITORING VOLUME AIR DALAM TANDON MENGGUNAKAN SENSOR TEKANAN BERBASIS IOT

AFLAH, MUHAMMAD ARIIQ and Sembiring, Sarmayanta and Hermansyah, Adi (2024) PERANCANGAN SISTEM MONITORING VOLUME AIR DALAM TANDON MENGGUNAKAN SENSOR TEKANAN BERBASIS IOT. Diploma thesis, Sriwijaya University.

[thumbnail of RAMA_56401_09030582024044.pdf] Text
RAMA_56401_09030582024044.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (4MB) | Request a copy
[thumbnail of RAMA_56401_09030582024044_TURNITIN.pdf] Text
RAMA_56401_09030582024044_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (11MB) | Request a copy
[thumbnail of RAMA_56401_09030582024044_0027017804_0030048909_01_front_ref.pdf] Text
RAMA_56401_09030582024044_0027017804_0030048909_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_56401_09030582024044_0027017804_0030048909_02.pdf] Text
RAMA_56401_09030582024044_0027017804_0030048909_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (685kB) | Request a copy
[thumbnail of RAMA_56401_09030582024044_0027017804_0030048909_03.pdf] Text
RAMA_56401_09030582024044_0027017804_0030048909_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_56401_09030582024044_0027017804_0030048909_04.pdf] Text
RAMA_56401_09030582024044_0027017804_0030048909_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_56401_09030582024044_0027017804_0030048909_05.pdf] Text
RAMA_56401_09030582024044_0027017804_0030048909_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (364kB) | Request a copy
[thumbnail of RAMA_56401_09030582024044_0027017804_0030048909_06_ref.pdf] Text
RAMA_56401_09030582024044_0027017804_0030048909_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (317kB) | Request a copy
[thumbnail of RAMA_56401_09030582024044_0027017804_0030048909_07_lamp.pdf] Text
RAMA_56401_09030582024044_0027017804_0030048909_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy

Abstract

The water volume monitoring system is a tool for detecting the volume of water in a container. In this way, this tool can make it easier for humans to know the conditions in a container and monitor the volume. This research designs a water volume monitoring system with water reservoirs as the object. The design was carried out using Esp32 as a microcontroller, MPX5700AP (absolute) sensor as a pressure detector, a Panther 250l tank as a water storage container and the Blynk IoT (Internet of THings) platform to monitor the condition readings on the reservoir. The absolute type MPX5700AP sensor itself is a pressure detection sensor in the range of 0 to 700 kPa (0 to 100 psi) in an object or container. The container used in this research was a 250l Panther brand tank which has a shape resembling a tube. So in calculating the volume of water, this system is programmed with a formula to find the volume in the tube. In finding the volume of water in the tank, the water level is needed. To find the height, this system utilizes calibration of sensor pressure data results and the actual height of the tank in the height range of 16cm – 80cm. So the water level calibration results are obtained which are then programmed into Esp32 to detect the water level in the reservoir. The results of the water level detection produced in the system show an average error of 3.27%. So overall the system is quite effective in monitoring water volume with a success percentage of 96.73% KEYWORDS : Blynk, Panther 250 l reservoir, MPX5700AP absolute type Sensor, Esp32, Water Height, Value Calibration, Tube Volume, Water Volume

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Blynk, Tandon Panther 250l, Sensor MPX5700AP absolute, Esp32, Ketinggian air, Kalibrasi nilai, Volume Tabung, Volume air.
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK7885-7895 Computer engineering. Computer hardware
Divisions: 09-Faculty of Computer Science > 56401-Computer Engineering (D3)
Depositing User: MUHAMMAD ARIIQ AFLAH
Date Deposited: 18 Dec 2024 03:03
Last Modified: 18 Dec 2024 03:03
URI: http://repository.unsri.ac.id/id/eprint/160573

Actions (login required)

View Item View Item