LUTHFI, M. INDRA and Chandra, Hendri (2017) ANALISA RESPON GETARAN TORSIONAL YANG TERJADI PADA POROS SUMBU VERTIKAL POMPA SENTRIFUGAL. Undergraduate thesis, Sriwijaya university.
|
Text
RAMA_21201_03121005037.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (26MB) | Request a copy |
|
|
Text
RAMA_21201_03121005037_0007046014_01 front ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (7MB) |
|
|
Text
RAMA_21201_03121005037_0007046014_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (4MB) | Request a copy |
|
|
Text
RAMA_21201_03121005037_0007046014_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (1MB) | Request a copy |
|
|
Text
RAMA_21201_03121005037_0007046014_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (6MB) | Request a copy |
|
|
Text
RAMA_21201_03121005037_0007046014_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (410kB) | Request a copy |
|
|
Text
RAMA_21201_03121005037_0007046014_06 ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (464kB) | Request a copy |
|
|
Text
RAMA_21201_03121005037_0007046014_07 lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (4MB) | Request a copy |
Abstract
Plant operating continuously causes the machines should operate continuously as well. Continuously operating machine requires extra maintenance. Pumps are essential components in a fluid distribution industry. Pump whose work continuously will get vibration phenomenon caused by components damage in pump. Vibration analysis needed to determine pump vibration. A machine will vibra/e if the excitation frequency is equal or more than his natural frequency. In conducting vibration analysis that cause of tangential force on centrifugal pump of shaft, not only theoretically but also needed simulation using MATLAB Software with input of the calculation on theoretical of mass moment of inertia of a shaft and impeller, torsional stiffness the shaft, natural frequency and excitation frequency. From the analysis and simulated, known that excitation frequency caused tangential force of the torsional vibration of excitation in 1 mm in excess of the value of his natural frequency vibration in 0,2903 mm which pump resonating and causing noise. The result of measurement with a measuring instrument vibration also indicates the pump on vibrates, especially at the measurementpoint IV in vertical axis worth amplitude 9,153 mm/s-Peak. Keywords : Shaft, Torsional stiffness, Natural frequency, Excitation frequency, Resonance, Vibration analysis, MATLAB.
| Item Type: | Thesis (Undergraduate) |
|---|---|
| Uncontrolled Keywords: | Poros, Kekakuan torsional, Frekuensi pribadi, Frekuensi eksitasi Resonansi, Analisa getaran, MATLAB |
| Subjects: | T Technology > TJ Mechanical engineering and machinery > TJ1040-1119 Machinery exclusive of prime movers > TJ1073.5.B38 Fluid-film bearings. |
| Divisions: | 03-Faculty of Engineering > 21201-Mechanical Engineering (S1) |
| Depositing User: | Ichlasyah Aisyah |
| Date Deposited: | 08 Sep 2025 01:28 |
| Last Modified: | 08 Sep 2025 01:28 |