MAISAROH, LISANA and Suheryanto, Suheryanto and Zainal, Fanani (2018) VALIDASI METODA POTENSIOMETRI UNTUK ANALISIS LOGAM KADMIUM (Cd) DALAM AIR LINDI. Undergraduate thesis, Sriwijaya University.
Preview |
Text
RAMA_47201_08031281419060_0025066004_0021086701_01_front_ref.pdf - Accepted Version Available under License Creative Commons Public Domain Dedication. Download (674kB) | Preview |
Text
RAMA_47201_08031281419060_0025066004_0021086701_02.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (259kB) | Request a copy |
|
Text
RAMA_47201_08031281419060_0025066004_0021086701_03.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (162kB) | Request a copy |
|
Text
RAMA_47201_08031281419060_0025066004_0021086701_04.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (142kB) | Request a copy |
|
Text
RAMA_47201_08031281419060_0025066004_0021086701_05.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (55kB) | Request a copy |
|
Text
RAMA_47201_08031281419060_0025066004_0021086701_06_ref.pdf - Bibliography Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (79kB) | Request a copy |
|
Text
RAMA_47201_08031281419060_0025066004_0021086701_07_lamp.pdf - Accepted Version Restricted to Repository staff only Available under License Creative Commons Public Domain Dedication. Download (447kB) | Request a copy |
Abstract
Testing of metal cadmium (Cd) using a potentiometric method using a concentration cell measurement system and a comparable cell measurement system was carried out. The purpose of the study was to validate, compare the validity level of the two systems, and their application for the determination of Cd metal in leachate at Sukawinatan landfill. The concentration cell measurement system consists of a solution of CdSO4.8H2O with different concentrations, in which there is a Cd electrode connected by a voltmeter and the two solutions are connected by the KNO3 salt bridge. While the comparative cell measurement system consists of two solutions of CdSO4.8H2O with different concentrations, in which there is a Cd electrode and a comparative electrode (Ag/AgCl) connected by a voltmeter and the two solutions are connected by the KNO3 salt bridge. The results showed that the same correlation coefficient of 0.999 with a concentration range of 1x10-2 to 1x10-6 mol/L, obtained %RSD value from the same two systems of 0.1%, with an average value of 91% accuracy (system concentration cell measurement) and 81% (comparative cell measurement system), then the LoD value obtained by the method of cell measurement system concentration of 0.20 mg/L and LoD method of comparison cell measurement system 0.19 mg/L. Based on the T test and the F test, the concentration cell measurement system is more valid than the comparison cell measurement system. The concentration of metal cadmium (Cd) was analyzed using the cell system concentration in ponds 1 to 5 as follows 105 mg/L ± 15.39 mg/L, 70.48 mg/L ± 9.44 mg/L, 9.52 mg/L ± 1.01 mg/L, 1.94 mg/L ± 0.20 mg/L and 0.56 mg/L ± 0.06 mg/L.
Item Type: | Thesis (Undergraduate) |
---|---|
Uncontrolled Keywords: | concentration cell, comparator cell, cadmium, leachate |
Subjects: | Q Science > QD Chemistry > QD1-999 Chemistry Q Science > QD Chemistry > QD71-142 Analytical chemistry |
Divisions: | 08-Faculty of Mathematics and Natural Science > 47201-Chemistry (S1) |