PENENTUAN TITIK LOKASI GANGGUAN PADA RELE JARAK DENGAN METODE IMPEDANSI DI JARINGAN TRANSMISI PT. PLN (PERSERO) GARDU INDUK KERAMASAN - GARDU INDUK SIMPANG TIGA 150 kV

NAZRI, MUHAMMAD and Thayib, Rudyanto (2021) PENENTUAN TITIK LOKASI GANGGUAN PADA RELE JARAK DENGAN METODE IMPEDANSI DI JARINGAN TRANSMISI PT. PLN (PERSERO) GARDU INDUK KERAMASAN - GARDU INDUK SIMPANG TIGA 150 kV. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_20201_03041381722098.pdf] Text
RAMA_20201_03041381722098.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (12MB) | Request a copy
[thumbnail of RAMA_202021_03041381722098_TURNITIN.pdf] Text
RAMA_202021_03041381722098_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (7MB) | Request a copy
[thumbnail of RAMA_20201_03041381722098_0006015605_01_front_ref.pdf]
Preview
Text
RAMA_20201_03041381722098_0006015605_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (8MB) | Preview
[thumbnail of RAMA_20201_03041381722098_0006015605_02.pdf] Text
RAMA_20201_03041381722098_0006015605_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (5MB) | Request a copy
[thumbnail of RAMA_20201_03041381722098_0006015605_03.pdf] Text
RAMA_20201_03041381722098_0006015605_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (655kB) | Request a copy
[thumbnail of RAMA_20201_03041381722098_0006015605_04.pdf] Text
RAMA_20201_03041381722098_0006015605_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_20201_03041381722098_0006015605_05.pdf] Text
RAMA_20201_03041381722098_0006015605_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (292kB) | Request a copy
[thumbnail of RAMA_20201_03041381722098_0006015605_06_ref.pdf] Text
RAMA_20201_03041381722098_0006015605_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (69kB) | Request a copy
[thumbnail of RAMA_20201_03041381722098_0006015605_07_lam.pdf] Text
RAMA_20201_03041381722098_0006015605_07_lam.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy

Abstract

Substation is a part of the transmission system in the distribution of electric power. The electric power transmission system can experience many disturbances, therefore protecting the substation is the most important part of the electric power transmission system. To be able to protect the transmission system, one of the main protection systems used is the distance relay. The distance relay will work by measuring the voltage at the relay point and the fault current seen from the relay, by dividing the magnitude of the voltage and current, then the impedance to the point of the disturbance can be determined. In order to cover the protected area and work reliably, the range of work of the distance relay is divided into 3 zones, namely zone 1, zone 2, and zone 3 with different reactions and setting times. In this final essay the type of disturbance that occurs is based on the recorded data, namely 1-phase to ground fault located in zone-1 with disturbance distance is 10,6 km from GI Keramasan. The results of the impedance calculation values that are calculated manually using the impedance method are: Zone-1 = 1,075547 Ω, Zone-2 = 3,340935 Ω, and for Zone-3 = 5,860924 Ω with an error percentage value of 0,135% for Zone-1, for Zone-2 it is 106,7% and for Zone-3 it is 99,691%. Then for the value of the calculation of the location of the disturbance and the percentage of error obtained a value of 10,588774 km and the percentage of error is 0,105906%.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Proteksi Sistem Transmisi, Gardu Induk, Rele Jarak, Zona Setting Rele Jarak, Impedansi
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK3001-3521 Distribution or transmission of electric power
Divisions: 03-Faculty of Engineering > 20201-Electrical Engineering (S1)
Depositing User: Muhammad Nazri
Date Deposited: 19 Nov 2021 03:02
Last Modified: 19 Nov 2021 03:02
URI: http://repository.unsri.ac.id/id/eprint/57633

Actions (login required)

View Item View Item