SISTEM PENGUKURAN SATURASI OKSIGEN DARAH DAN DETAK JANTUNG MENGGUNAKAN PULSE OXIMETER BERBASIS LOGIKA FUZZY

DESIANA, AMELIA and Malik, Reza Firsandaya (2018) SISTEM PENGUKURAN SATURASI OKSIGEN DARAH DAN DETAK JANTUNG MENGGUNAKAN PULSE OXIMETER BERBASIS LOGIKA FUZZY. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_56201_09111001052_ 0025047609_01_front_ref.pdf]
Preview
Text
RAMA_56201_09111001052_ 0025047609_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (562kB) | Preview
[thumbnail of RAMA_56201_09111001052_ 0025047609_02.pdf] Text
RAMA_56201_09111001052_ 0025047609_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (407kB) | Request a copy
[thumbnail of RAMA_56201_09111001052_ 0025047609_03.pdf] Text
RAMA_56201_09111001052_ 0025047609_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (499kB) | Request a copy
[thumbnail of RAMA_56201_09111001052_ 0025047609_04.pdf] Text
RAMA_56201_09111001052_ 0025047609_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (327kB) | Request a copy
[thumbnail of RAMA_56201_09111001052_ 0025047609_05.pdf] Text
RAMA_56201_09111001052_ 0025047609_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (28kB) | Request a copy
[thumbnail of RAMA_56201_09111001052_ 0025047609_06_ref.pdf] Text
RAMA_56201_09111001052_ 0025047609_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (78kB) | Request a copy
[thumbnail of RAMA_56201_09111001052_ 0025047609_07_lamp.pdf] Text
RAMA_56201_09111001052_ 0025047609_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (936kB) | Request a copy

Abstract

Pulse Oximeter is a tool for measuring oxygen saturation (SpO2) from hemoglobin using a non-invasive method. This tool can also measure the heart rate (heartrate). Oximeters are used by placing fingertips on sensors that consist of red and infrared leads. This study was conducted to monitor the condition of the patient from a distance without having to meet face to face by implementing Fuzzy Kohonen Network. Fuzzy Kohonen Network method is used as an algorithm to monitor patient condition with two parameters of Pulse Oximeter as oxygen saturation detector (SpO2) and heartbeat sensor as heart rate detector (BPM). Scenario used in this research is to test for normal, sick and critical category condition. For testing conditions of the normal category the output of the output will only appear on the serial monitor or Short Message Service (SMS) not sent, while for the category of pain and critical results of the output will be sent via GSM module in the form of Short Message Service (SMS) and can also seen on serial monitor. This research also measured instrument accuracy between Pulse Oximeter and Fingertip Pulse with average value for oxygen saturation (SpO2) of 97.73% and 99.2% for heart rate (BPM).

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Pulse Oxmeter, Fuzzy Kohonen Network, Short Message Service (SMS), Heartbeat Sensor, Oxygen Saturation (SpO2), Heartbeat (BPM), Fingertip
Subjects: T Technology > TS Manufactures > TS155-194 Production management. Operations management > TS183.G76 Manufacturing processes, Automation. Production control. CAD/CAM systems. Computer integrated manufacturing systems. Robots, Industrial.
Divisions: 09-Faculty of Computer Science > 56201-Computer Systems (S1)
Depositing User: Mrs Sri Astuti
Date Deposited: 23 Sep 2019 07:18
Last Modified: 23 Sep 2019 07:18
URI: http://repository.unsri.ac.id/id/eprint/8603

Actions (login required)

View Item View Item