ANALISIS PENGARUH DIAMETER KAWAT KUMPARAN PADA MESIN STERILISASI ALAT MEDIS PORTABEL

HANAFI, AKMAL SYUKRI and Rahmawati, Rahmawati (2023) ANALISIS PENGARUH DIAMETER KAWAT KUMPARAN PADA MESIN STERILISASI ALAT MEDIS PORTABEL. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_20201_03041281823041.pdf] Text
RAMA_20201_03041281823041.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (3MB) | Request a copy
[thumbnail of RAMA_20201_03041281823041_TURNITIN.pdf] Text
RAMA_20201_03041281823041_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (2MB) | Request a copy
[thumbnail of RAMA_20201_03041281823041_0026117701_01_front_ref.pdf] Text
RAMA_20201_03041281823041_0026117701_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_20201_03041281823041_0026117701_02.pdf] Text
RAMA_20201_03041281823041_0026117701_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (397kB) | Request a copy
[thumbnail of RAMA_20201_03041281823041_0026117701_03.pdf] Text
RAMA_20201_03041281823041_0026117701_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (295kB) | Request a copy
[thumbnail of RAMA_20201_03041281823041_0026117701_04.pdf] Text
RAMA_20201_03041281823041_0026117701_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (344kB) | Request a copy
[thumbnail of RAMA_20201_03041281823041_0026117701_05.pdf] Text
RAMA_20201_03041281823041_0026117701_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (6kB) | Request a copy
[thumbnail of RAMA_20201_03041281823041_0026117701_06_ref.pdf] Text
RAMA_20201_03041281823041_0026117701_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (76kB) | Request a copy
[thumbnail of RAMA_20201_03041281823041_0026117701_07_lamp.pdf] Text
RAMA_20201_03041281823041_0026117701_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy

Abstract

Every hospital activity must meet agreed medical standards, including sterilization of the use of medical devices. With the dry heat sterilization method in the oven, a sterilization machine is needed that can be easily carried in a portable form. The use of wire coils as heat conductors is needed to make sterilization machines, where the larger the diameter of the coil can reduce the power used and the smaller the diameter of the coil can accelerate temperature changes in the coil. This research was carried out by assembling a sterilization machine with various components needed so that measurements can be made of voltage, current, time to reach sterile temperatures and calculation of the power produced. In making portable medical device sterilizers, the use of coil wires with diameters of 0.8 mm, 1 mm, 1.2 mm, and 1.3 mm has been tested as a trigger for hot temperatures in machines where the coil wire with a diameter of 0.8 mm is able to provide the best results than other coil wire diameters. Of the four variations in coil wire diameter, coil wire with a diameter of 0.8 mm produces a maximum value with a voltage of 56.2 volts, an electric current of 4.08 Amperes, and the fastest heating time of 18.51 minutes. This is appropriate based on the relationship between diameter and resistance where the smaller the diameter, the greater the resistance value in a circuit which can affect the value of current and voltage flowing. The largest power value comes from a 0.8 mm diameter coil wire rated at 114.64 Watts. This is based on the correlation between the power value, the voltage and current value, that is, the greater the current value, the greater the power value produced. The smallest power value comes from a coil wire with a diameter of 1.3 mm valued at 19.31 Watts.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: Sterilization Machine, Wire Diameter, Power
Subjects: T Technology > TK Electrical engineering. Electronics Nuclear engineering > TK4001-4102 Applications of electric power
Divisions: 03-Faculty of Engineering > 20201-Electrical Engineering (S1)
Depositing User: Akmal Syukri Hanafi
Date Deposited: 22 May 2023 06:45
Last Modified: 22 May 2023 06:45
URI: http://repository.unsri.ac.id/id/eprint/104508

Actions (login required)

View Item View Item