STUDI EKSPERIMENTAL UJI KONDUKTIVITAS LISTRIK MORTAR DENGANSERBUK GRAFIT SEBAGAI PENGGANTI AGREGAT HALUS

BASKORO, SULTAN HADRIAN ALWARD RAFIE and Iqbal, Maulid Muhammad and Saloma, Saloma (2024) STUDI EKSPERIMENTAL UJI KONDUKTIVITAS LISTRIK MORTAR DENGANSERBUK GRAFIT SEBAGAI PENGGANTI AGREGAT HALUS. Undergraduate thesis, Sriwijaya University.

[thumbnail of RAMA_22201_03011282025079.pdf] Text
RAMA_22201_03011282025079.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (1MB) | Request a copy
[thumbnail of RAMA_22201_03011282025079_TURNITIN.pdf] Text
RAMA_22201_03011282025079_TURNITIN.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (16MB) | Request a copy
[thumbnail of RAMA_22201_03011282025079_0009096012_0031107601_01_front_ref.pdf] Text
RAMA_22201_03011282025079_0009096012_0031107601_01_front_ref.pdf - Accepted Version
Available under License Creative Commons Public Domain Dedication.

Download (1MB)
[thumbnail of RAMA_22201_03011282025079_0009096012_0031107601_02.pdf] Text
RAMA_22201_03011282025079_0009096012_0031107601_02.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (443kB) | Request a copy
[thumbnail of RAMA_22201_03011282025079_0009096012_0031107601_03.pdf] Text
RAMA_22201_03011282025079_0009096012_0031107601_03.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (301kB) | Request a copy
[thumbnail of RAMA_22201_03011282025079_0009096012_0031107601_04.pdf] Text
RAMA_22201_03011282025079_0009096012_0031107601_04.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (249kB) | Request a copy
[thumbnail of RAMA_22201_03011282025079_0009096012_0031107601_05.pdf] Text
RAMA_22201_03011282025079_0009096012_0031107601_05.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (84kB) | Request a copy
[thumbnail of RAMA_22201_03011282025079_0009096012_0031107601_06_ref.pdf] Text
RAMA_22201_03011282025079_0009096012_0031107601_06_ref.pdf - Bibliography
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (77kB) | Request a copy
[thumbnail of RAMA_22201_03011282025079_0009096012_0031107601_07_lamp.pdf] Text
RAMA_22201_03011282025079_0009096012_0031107601_07_lamp.pdf - Accepted Version
Restricted to Repository staff only
Available under License Creative Commons Public Domain Dedication.

Download (679kB) | Request a copy

Abstract

Conductive mortar is a type of mortar specifically designed to possess the ability to conduct electricity. Conductive mortar falls under the category of smart mortar. This mortar is engineered with special properties that enable electrical conductivity, something that conventional mortar does not have. Graphite powder can be used as a substitute for fine aggregate or sand. This research utilizes variations in age and graphite powder concentration at 0%, 25%, 50%, 75%, and 100%, with a cement-to-sand ratio of 1:2.75 and a water-cement ratio (w/c) of 0.485. Fresh mortar testing includes setting time tests and slump flow tests, while hardened mortar testing includes compressive strength tests, density tests, and electrical conductivity tests. Based on the setting time test, conductive mortar with a 25% GP (Graphite Powder) variation, having an initial setting time of 329 minutes and a final setting time of 555 minutes, showed the fastest setting time compared to other variations. According to the slump flow values, the specimen with a 25% GP variation had the highest flowability compared to the other variations. The density and compressive strength tests on the specimen with a 25% GP variation, after curing in water for 7 days, showed the highest values compared to other variations, with values of 1765 kg/m3 and 9.8 MPa, respectively. The electrical conductivity of the specimen with a 100% GP variation after curing in water for 7 days showed the highest value compared to other variations, amounting to 27060 μS/m.

Item Type: Thesis (Undergraduate)
Uncontrolled Keywords: : Conductive mortar, graphite powder, smart mortar, kuat tekan, berat jenis, konduktivitas listrik.
Subjects: T Technology > TA Engineering (General). Civil engineering (General) > TA401-492 Materials of engineering and construction. Mechanics of materials > TA418.9.C6.B538 Composite materials. Polymeric composites. Fibrous composites. Biomass chemicals. TECHNOLOGY & ENGINEERING / Material Science. SCIENCE / Chemistry / General
Divisions: 03-Faculty of Engineering > 22201-Civil Engineering (S1)
Depositing User: Sultan Hadrian Alward Rafie Baskoro
Date Deposited: 10 Sep 2024 01:35
Last Modified: 27 Sep 2024 01:37
URI: http://repository.unsri.ac.id/id/eprint/156882

Actions (login required)

View Item View Item